Evidence map›Paper›PMID 36850411›Full record

ArticleSensors (Basel, Switzerland)2023

Validation of 3D Knee Kinematics during Gait on Treadmill with an Instrumented Knee Brace.

Nicolas Reneaud, Raphaël Zory, Olivier Guérin, Luc Thomas, Serge S Colson, Pauline Gerus, Frédéric Chorin

Registry-linked trialAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04225182 (Evaluation of the Effectiveness of a Muscular Strengthening Protocol With an Instrumented Orthosis for Gonarthrosis Patients), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04225182 nacompletednot on this map

Evaluation of the Effectiveness of a Muscular Strengthening Protocol With an Instrumented Orthosis for Gonarthrosis Patients

TypeinterventionalSponsorCentre Hospitalier Universitaire de NiceRan2020 to 2022Enrolled65ConditionsGonarthrosisArmstraditional rehabilitation protocol, with instrumented Orthosis
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nicolas ReneaudUniversité Côte d'Azur, LAMHESS, 06205 Nice, France.ORCID 0000-0003-1486-059X
Raphaël ZoryUniversité Côte d'Azur, LAMHESS, 06205 Nice, France.ORCID 0000-0003-3566-3229
Olivier GuérinUniversité Côte d'Azur, CNRS, INSERM, IRCAN, 06107 Nice, France.
Luc ThomasTed Orthopedics, 37 Rue Guibal, 13003 Marseille, France.
Serge S ColsonUniversité Côte d'Azur, LAMHESS, 06205 Nice, France.ORCID 0000-0002-3315-9486
Pauline GerusUniversité Côte d'Azur, LAMHESS, 06205 Nice, France.ORCID 0000-0003-3266-1578
Frédéric ChorinUniversité Côte d'Azur, LAMHESS, 06205 Nice, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To test a novel instrumented knee brace intended for use as a rehabilitation system, based on inertial measurement units (IMU) to monitor home-based exercises, the device was compared to the gold standard of motion analysis. The purpose was to validate a new calibration method through functional tasks and assessed the value of adding magnetometers for motion analysis. Thirteen healthy young adults performed a 60-second gait test at a comfortable walking speed on a treadmill. Knee kinematics were captured simultaneously, using the instrumented knee brace and an optoelectronic camera system (OCS). The intraclass correlation coefficient (ICC) showed excellent reliability for the three axes of rotation with and without magnetometers, with values ranging between 0.900 and 0.972. Pearson's r coefficient showed good to excellent correlation for the three axes, with the root mean square error (RMSE) under 3° with the IMUs and slightly higher with the magnetometers. The instrumented knee brace obtained certain clinical parameters, as did the OCS. The instrumented knee brace seems to be a valid tool to assess ambulatory knee kinematics, with an RMSE of <3°, which is sufficient for clinical interpretations. Indeed, this portable system can obtain certain clinical parameters just as well as the gold standard of motion analysis. However, the addition of magnetometers showed no significant advantage in terms of enhancing accuracy.

Indexed as

GaitKnee JointBiomechanical PhenomenaHumansReproducibility of ResultsRotationYoung Adultconnected knee bracegaitinertial measurement unitjoint kinematicsvalidity

Identifiers

PMID36850411
PMCPMC9968020

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.