Evidence map›Paper›PMID 36850239›Full record

ArticlePolymers2023

Retentive Forces and Deformation of Fitting Surface in RPD Clasp Made of Polyether-Ether-Ketone (PEEK).

Sunil Kumar Vaddamanu, Fahad Hussain Alhamoudi, Saurabh Chaturvedi, Nasser M Alqahtani, Mohamed Khaled Addas, Mohammad Al Alfarsi, Rajesh Vyas, Masroor Ahmed Kanji, Mohammad A Zarbah, Waleed M S Alqahtani and 3 more

Abstract read
In one paragraph

Article in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Retention of 3-D-Printed, Milled, and Conventionally Fabricated Occlusal Splints.Medical science monitor : international medical journal of experimental and clinical research · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Sunil Kumar VaddamanuDepartment of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia.
Fahad Hussain AlhamoudiDepartment of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia.ORCID 0000-0002-8391-1787
Saurabh ChaturvediDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.ORCID 0000-0001-7832-3772
Nasser M AlqahtaniDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.
Mohamed Khaled AddasDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.ORCID 0000-0003-2200-2966
Mohammad Al AlfarsiDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.
Rajesh VyasDepartment of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia.
Masroor Ahmed KanjiDepartment of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia.
Mohammad A ZarbahDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.
Waleed M S AlqahtaniDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.
Saeed M AlqahtaniDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.
Adel M AbdelmonemDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.
Asim Elsir ElmahdiDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.

Funding

King Khalid University RGP.1/207/43
6 · The paper itself

Abstract

backgroundPolyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp. This study aimed to examine the retentive forces and the fitting surface (inner surface) deformation of clasps made from PEEK and compare it with cobalt-chromium (Co-Cr) clasp.

methodsForty-two circumferential clasps (14 Co-Cr and 28 PEEK) were fabricated and divided into two groups with clasp undercuts (0.25 mm and 0.5 mm) with thicknesses of 1 mm and 1.5 mm. Each was examined for retentive forces after cycle test on its abutment for 360 cycles. Initial and final retentive forces were recorded. The fitting surface deformation was determined using 3-Matic research analysis software.

resultsThe results revealed that highest mean initial retentive force was of Co-Cr clasps with 0.50 mm undercut 22.26 N (±10.15 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 3.35 N (±0.72 N) and highest mean final retentive force was the Co-Cr clasps with 0.50 mm undercut 21.40 N (±9.66 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 2.71 N (±0.47 N). PEEK clasps had a lower retentive force than Co-Cr clasps with 0.50 undercut. PEEK clasps (1.5 mm) at 0.25 mm undercut had the least deformation (35.3 µm). PEEK showed significantly less deformation (

conclusionThe deformation of PEEK clasps fitting surface was lower than Co-Cr clasps and retentive forces were close to the Co-Cr clasps, suggesting the use of PEEK as an aesthetic clasp option for RPD framework.

Indexed as

circumferential claspCo-Crdeformationpolyether-ether-ketone (PEEK)RPD

Identifiers

PMID36850239
PMCPMC9959771

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.