Evidence map›Paper›PMID 36849976›Full record

ArticleWorld journal of surgical oncology2023

Comparison of single-pore non-liposuction near-infrared laparoscopy with conventional open surgery for axillary sentinel lymph node biopsy in patients with early breast cancer: a single-center, small-sample retrospective study.

Cheng-Cai Yao, Changchun Liu, Jiayi Xian

Open access · goldAbstract read
In one paragraph

Article in World journal of surgical oncology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Cheng-Cai YaoSixth Affiliated Hospital of South China University of Technology, and Sixth Clinical College of South China University of Technology, Foshan, 528225, People's Republic of China. 744875674@qq.com.
Changchun LiuDepartment of Breast Surgery, Sixth Affiliated Hospital of South China University of Technology, and Sixth Clinical College of South China University of Technology, Foshan, 528225, People's Republic of China.
Jiayi XianDepartment of Breast Surgery, Sixth Affiliated Hospital of South China University of Technology, and Sixth Clinical College of South China University of Technology, Foshan, 528225, People's Republic of China.
South China University of Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to compare the effects of single-pore non-liposuction near-infrared (NIR) endoscopic surgery and traditional open surgery for axillary sentinel lymph node biopsy (SLNB) in patients with early breast cancer (EBC).

methodsThe clinical pathological data of 61 patients with EBC who underwent axillary SLNB using indocyanine green (ICG) combined with carbon nanoparticle suspension (CNS) were retrospectively collected. Thirty patients received SLNB through single-pore non-liposuction NIR endoscopic surgery (endoscopic group), and the remaining 31 received SLNB through open-incision surgery (open group). The success rate, operation time, volume of intraoperative bleeding, postoperative axillary drainage, axillary extubation time, and the occurrence of postoperative complications were compared between the groups along with the total number of sentinel lymph nodes (SLNs), luminous SLNs, stained SLNs, and the pathological positivity rate of the SLNs.

resultsAll patients underwent SLNB with a 100% success rate. SLNB operation times of the endoscopic group were longer than those of the open group (t = 3.963, P = 0.000), and the volume of axillary drainage was inferior (t = 3.035, P = 0.004). However, there were no differences in the intraoperative bleeding volumes, axillary extubation times, and postoperative complications (P > 0.05). In the Open group, the mean number of SLNs was 5.12 ± 2.16, and the pathological positivity rate was 13.53%; in the Endoscopic group, these numbers were 4.89 ± 1.73 and 12.39%. The mean number of SLNs detected (t = 0.458, P = 0.649) and the pathological positivity rates (χ2 = 0.058, P = 0.810) did not differ between the two groups. All 61 patients were followed for a median of 14.6 months. There were no local recurrences or distant metastases.

conclusionsOur single-center results reveal that single-hole non-liposuction NIR endoscopic axillary SLNB is not inferior to open SLNB and may be an appropriate option for patients with early breast cancer who desire breast preservation with fewer incisions.

trial registrationThis retrospective study was "retrospectively registered" at the Sixth Affiliated Hospital of South China University of Technology (no. 2020105) and in National Medical Research Registration and Archival Information System ( https://www.medicalresearch.org.cn , number: MR-44-21-004727).

Indexed as

Breast NeoplasmsLaparoscopySurgical WoundFemaleHumansPostoperative ComplicationsRetrospective StudiesSentinel Lymph Node BiopsyCarbon nanoparticle suspensionEarly breast cancerIndocyanide greenNear-infrared endoscopySentinel lymph node biopsy

Identifiers

PMID36849976
PMCPMC9972847
OpenAlexW4322487302

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked