Evidence map›Paper›PMID 36843092›Full record

ArticleJournal of orthopaedic surgery and research2023

Inadequate proximal screw fixation increases risk of failure following plate fixation of diaphyseal humerus fractures.

Manisha R Mistry, Jimmy Tat, Rafi Husain, Ujash Sheth, Robin R Richards, Diane Nam

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Manisha R MistryJ159 - Division of Orthopaedic Surgery, The Ottawa Hospital Civic Campus, The University of Ottawa, Ottawa, ON, K1Y 4E9, Canada. manmistry@toh.ca.
Jimmy TatDepartment of Surgery, Division of Orthopaedic Surgery, University of Toronto, Toronto, ON, Canada.
Rafi HusainDepartment of Surgery, Division of Orthopaedic Surgery, University of Toronto, Toronto, ON, Canada.
Ujash ShethDepartment of Surgery, Division of Orthopaedic Surgery, University of Toronto, Toronto, ON, Canada.
Robin R RichardsDepartment of Surgery, Division of Orthopaedic Surgery, University of Toronto, Toronto, ON, Canada.
Diane NamDepartment of Surgery, Division of Orthopaedic Surgery, University of Toronto, Toronto, ON, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOperative treatment of humeral shaft fractures (AO/OTA 12) is being performed more frequently. Accordingly, it is important to understand the complications associated with plate fixation. This study analyzes risk factors associated with mechanical failure following plate fixation of humeral shaft fractures in order to further elucidate the mode and location of failure.

methodsA retrospective review of 351 humeral shaft fractures was completed at a single level I trauma center. Eleven of eighty-five humeral shaft fractures had aseptic mechanical failure requiring revision (12.9%), following initial plate fixation. Fracture characteristics (AO type, comminution, location) and fracture fixation (plate type, multiplanar, number of screws proximal and distal to the fracture) were compared between aseptic mechanical failure and those without failure. A forward stepwise logistic regression analysis was performed to determine any significant predictors of aseptic mechanical failure.

resultsThere was significant differences in fixation between the aseptic mechanical failure group and those without failure, specifically in the number of screws for proximal fixation (p = 0.008) and distal fixation (p = 0.040). In the aseptic mechanical failure group, patients tended to have less than < 8 cortices of proximal fixation (82%) and less than < 8 cortices of distal fixation (64%). Conversely, in patients without mechanical failure there was a tendency to have greater than > 8 cortices in both the proximal (62%) and distal fixation (70%). A forward stepwise logistic regression analysis found that less than < 8 cortices of proximal fixation was a significant predictor of aseptic failure, OR 7.96 (p = 0.011). We think this can be accounted for due to the variable bone quality, thinner cortices and multiple torsional forces in the proximal shaft that may warrant special consideration for fixation.

conclusionThe current dogma of humeral shaft fracture stabilization is to use a minimum of 3 screws proximal and distal to the fracture, however the current study demonstrates this is associated with higher rates of mechanical failure. In contrast, 4 bicortical screws or more of fixation on either side of the fracture had lower failure rates and may help to reduce the risk of mechanical failure. Level of Evidence Level III.

Indexed as

Humeral FracturesShoulder FracturesBone PlatesBone ScrewsFracture FixationFracture Fixation, InternalHumansHumerusRetrospective StudiesRisk FactorsAseptic failureComplicationsFractureHumerus shaftPeriprosthetic failurePlate fixation

Identifiers

PMID36843092
PMCPMC9969619

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.