ArticleJournal of biomechanics2023

Pulse wave imaging of a stenotic artery model with plaque constituents of different stiffnesses: Experimental demonstration in phantoms and fluid-structure interaction simulation.

Nima Mobadersany, Nirvedh H Meshram, Paul Kemper, C V Sise, Grigorios M Karageorgos, Pengcheng Liang, Gerard A Ateshian, Elisa E Konofagou

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Nima MobadersanyDepartment of Biomedical Engineering, Columbia University, New York, NY, United States.
Nirvedh H MeshramDepartment of Biomedical Engineering, Columbia University, New York, NY, United States.
Paul KemperDepartment of Biomedical Engineering, Columbia University, New York, NY, United States.
C V SiseDepartment of Biomedical Engineering, Columbia University, New York, NY, United States.
Grigorios M KarageorgosDepartment of Biomedical Engineering, Columbia University, New York, NY, United States.
Pengcheng LiangDepartment of Biomedical Engineering, Columbia University, New York, NY, United States.
Gerard A AteshianDepartment of Biomedical Engineering, Columbia University, New York, NY, United States; Department of Mechanical Engineering, Columbia University, New York, NY, United States.
Elisa E KonofagouDepartment of Biomedical Engineering, Columbia University, New York, NY, United States; Department of Radiology, Columbia University, New York, New York, NY, United States. Electronic address: ek2191@columbia.edu.
Columbia University · US

Funding

Carotid plaque assessment using Pulse Wave ImagingR01HL135734 · NHLBI · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI KONOFAGOU, ELISA E. · 2017 to 2020
$2.5M
NHLBI NIH HHS R01 HL135734
6 · The paper itself

Abstract

Vulnerable plaques associated with softer components may rupture, releasing thrombotic emboli to smaller vessels in the brain, thus causing an ischemic stroke. Pulse Wave Imaging (PWI) is an ultrasound-based method that allows for pulse wave visualization while the regional pulse wave velocity (PWV) is mapped along the arterial wall to infer the underlying wall compliance. One potential application of PWI is the non-invasive estimation of plaque's mechanical properties for investigating its vulnerability. In this study, the accuracy of PWV estimation in stenotic vessels was investigated by computational simulation and PWI in validation phantoms to evaluate this modality for assessing future stroke risk. Polyvinyl alcohol (PVA) phantoms with plaque constituents of different stiffnesses were designed and constructed to emulate stenotic arteries in the experiment, and the novel fabrication process was described. Finite-element fluid-structure interaction simulations were performed in a stenotic phantom model that matched the geometry and parameters of the experiment in phantoms. The peak distension acceleration of the phantom wall was tracked to estimate PWV. PWVs of 2.57 ms

Indexed as

Plaque, AtheroscleroticPulse Wave AnalysisArteriesDiagnostic ImagingHumansPhantoms, ImagingCarotid plaqueFluid–structure interaction simulationPulse wave imagingPulse wave velocityPVA phantom