Evidence map›Paper›PMID 36842082›Full record

ArticleMedical physics2023

Bend-insensitive fiber optic ultrasonic tracking probe for cardiovascular interventions.

Sunish J Mathews, Callum Little, Edward Zhang, Paul Beard, Tara Mastracci, Roby Rakhit, Adrien E Desjardins

Open access · hybridAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Sunish J MathewsWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
Callum LittleDepartment of Cardiology, Imperial College Healthcare NHS Foundation Trust, London, UK.
Edward ZhangDepartment of Medical Physics and Biomedical Engineering, University College London, London, UK.
Paul BeardWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
Tara MastracciDepartment of Cardiology, Royal Free London NHS Foundation Trust, London, UK.
Roby RakhitDepartment of Cardiology, Royal Free London NHS Foundation Trust, London, UK.
Adrien E DesjardinsWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
University College London · GBRoyal Free London NHS Foundation Trust · GBImperial College Healthcare NHS Trust · GBWellcome / EPSRC Centre for Interventional and Surgical Sciences · GB

Funding

Wellcome Trust
6 · The paper itself

Abstract

backgroundTransesophageal echocardiography (TEE) is widely used to guide medical device placement in minimally invasive cardiovascular procedures. However, visualization of the device tip with TEE can be challenging. Ultrasonic tracking, enabled by an integrated fiber optic ultrasound sensor (FOUS) that receives transmissions from the TEE probe, is very well suited to improving device localization in this context. The problem addressed in this study is that tight deflections of devices such as a steerable guide catheter can result in bending of the FOUS beyond its specifications and a corresponding loss of ultrasound sensitivity. PURPOSE: A bend-insensitive FOUS was developed, and its utility with ultrasonic tracking of a steerable tip during TEE-based image guidance was demonstrated.

methodsFiberoptic ultrasound sensors were fabricated using both standard and bend insensitive single mode fibers and subjected to static bending at the distal end. The interference transfer function and ultrasound sensitivities were compared for both types of FOUS. The bend-insensitive FOUS was integrated within a steerable guide catheter, which served as an exemplar device; the signal-to-noise ratio (SNR) of tracking signals from the catheter tip with a straight and a fully deflected distal end were measured in a cardiac ultrasound phantom for over 100 frames.

resultsWith tight bending at the distal end (bend radius < 10 mm), the standard FOUS experienced a complete loss of US sensitivity due to high attenuation in the fiber, whereas the bend-insensitive FOUS had largely unchanged performance, with a SNR of 47.7 for straight fiber and a SNR of 36.8 at a bend radius of 3.0 mm. When integrated into the steerable guide catheter, the mean SNRs of the ultrasonic tracking signals recorded with the catheter in a cardiac phantom were similar for straight and fully deflected distal ends: 195 and 163.

conclusionThe FOUS fabricated from bend-insensitive fiber overcomes the bend restrictions associated with the FOUS fabricated from standard single mode fiber, thereby enabling its use in ultrasonic tracking in a wide range of cardiovascular devices.

Indexed as

Fiber Optic TechnologyUltrasonicsCathetersHeartUltrasonographybend-insensitive fibercardiovascular interventionsfiber optic ultrasound sensortransesophageal electrocardiographyultrasonic tracking

Identifiers

PMID36842082
PMCPMC10615325
OpenAlexW4322101414

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.