Evidence map›Paper›PMID 36841890›Full record

ArticleAnnals of biomedical engineering2023

Micro-CT Imaging and Mechanical Properties of Ovine Ribs.

Patricia K Thomas, Juliette Caffrey, K Eddie Afetse, Nahir A Habet, Kyle Ondar, Caitlin M Weaver, Michael Kleinberger, Philip Brown, F Scott Gayzik

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Patricia K ThomasDepartment of Biomedical Engineering, Wake Forest School of Medicine, Winston-Salem, USA.ORCID http://orcid.org/0000-0002-5158-9084
Juliette CaffreyDepartment of Biomedical Engineering, Wake Forest School of Medicine, Winston-Salem, USA.
K Eddie AfetseMusculoskeletal Research Institute, Atrium Health, Charlotte, USA.
Nahir A HabetMusculoskeletal Research Institute, Atrium Health, Charlotte, USA.
Kyle OndarDepartment of Biomedical Engineering, Wake Forest School of Medicine, Winston-Salem, USA.
Caitlin M WeaverArmy Research Directorate, DEVCOM Army Research Laboratory, Adelphi, USA.
Michael KleinbergerArmy Research Directorate, DEVCOM Army Research Laboratory, Adelphi, USA.
Philip BrownDepartment of Biomedical Engineering, Wake Forest School of Medicine, Winston-Salem, USA.
F Scott GayzikDepartment of Biomedical Engineering, Wake Forest School of Medicine, Winston-Salem, USA. sgayzik@wakehealth.edu.
Wake Forest University · USCarolina Musculoskeletal Institute · USDEVCOM Army Research Laboratory · US

Funding

DEVCOM Army Research Laboratory W911NF2120034
6 · The paper itself

Abstract

The use of ovine animal models in the study of injury biomechanics and modeling is increasing, due to their favorable size and other physiological characteristics. Along with this increase, there has also been increased interest in the development of in silico ovine models for computational studies to compliment physical experiments. However, there remains a gap in the literature characterizing the morphological and mechanical characteristics of ovine ribs. The objective of this study therefore is to report anatomical and mechanical properties of the ovine ribs using microtomography (micro-CT) and two types of mechanical testing (quasi-static bending and dynamic tension). Using microtomography, young ovine rib samples obtained from a local abattoir were cut into approximately fourteen 38 mm sections and scanned. From these scans, the cortical bone thickness and cross-sectional area were measured, and the moment of inertia was calculated to enhance the mechanical testing data. Based on a standard least squares statistical model, the cortical bone thickness varied depending on the region of the cross-section and the position along the length of the rib (p < 0.05), whereas the cross-sectional area remained consistent (p > 0.05). Quasi-static three-point bend testing was completed on ovine rib samples, and the resulting force-displacement data was analyzed to obtain the stiffness (44.67 ± 17.65 N/mm), maximum load (170.54 ± 48.28 N) and displacement at maximum load (7.19 ± 2.75 mm), yield load (167.81 ± 48.12 N) and displacement at yield (6.10 ± 2.25 mm), and the failure load (110.90 ± 39.30 N) and displacement at failure (18.43 ± 2.10 mm). The resulting properties were not significantly affected by the rib (p > 0.05), but by the animal they originated from (p < 0.05). For the dynamic testing, samples were cut into coupons and tested in tension with an average strain rate of 18.9 strain/sec. The resulting dynamic testing properties of elastic modulus (5.16 ± 2.03 GPa), failure stress (63.29 ± 14.02 MPa), and failure strain (0.0201 ± 0.0052) did not vary based on loading rate (p > 0.05).

Indexed as

Mechanical PhenomenaRibsAnimalsBiomechanical PhenomenaCortical BoneSheepStress, MechanicalX-Ray MicrotomographyMaterial characterizationMicro-CTOvine

Identifiers

PMID36841890
OpenAlexW4322007458

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.