Evidence map›Paper›PMID 36840343›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2023

Comparison of the Fractured and Non-Fractured Orbit Before and After Surgery Using a Titanium Implant or a Resorbable Poly-d,l-lactic Acid (PDLLA) Implant: A Study from a Single Center in Niš, Serbia of 58 Patients with Unilateral Orbital Floor Fracture Using Volumetric Measurement.

Predrag Radović, Sonja Janković, Milovan Papović, Marša Leone Dimitrijević, Dragan Krasić

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Predrag RadovićDepartment of Maxillofacial Surgery, Clinic of Dental Medicine, Medical Faculty, University of Niš, Niš, Serbia.
Sonja JankovićCenter for Radiology, University Clinical Center Niš, Niš, Serbia.
Milovan PapovićDepartment of Maxillofacial Surgery, Clinic of dental medicine Niš, Niš, Serbia.
Marša Leone DimitrijevićDepartment of Maxillofacial Surgery, Clinic of Dental Medicine Niš, Niš, Serbia.
Dragan KrasićDepartment of Maxillofacial Surgery, Clinic of Dental Medicine, Medical Faculty, University of Niš, Niš, Serbia.
University of Nis · RS

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND A fracture of the orbital floor can lead to complications such as enophthalmos, impaired eye motility, or diplopia, which is why it is necessary to reconstruct the bony walls of the orbit. This study from a single center in Niš, Serbia, included 58 patients with unilateral orbital floor fracture and aimed to use volumetric measurement to compare the fractured and non-fractured orbit before and after surgery using a titanium implant or a resorbable poly-d, l-lactic acid (PDLLA) implant. MATERIAL AND METHODS From 2018 to 2022, a total of 58 patients with unilateral orbital floor fractures were treated at the Clinic of Dental Medicine, Niš. Computed tomography examination was used for volumetric measurement of the fractured and non-fractured (contralateral) orbit before and after the surgical procedure. A titanium implant was used in 31 patients, and a PDLLA implant was used in 27 patients. RESULTS Orbital volume ratio did not differ statistically significantly in relation to the type of implant (P=0.591). The postoperative volume did not differ statistically significantly from the volume of the contralateral side (titanium, P=0.212; PDLLA, P=0.232). There was a significant correlation between orbital volume and enophthalmos both before and after surgery (P=0.012, P=0.018, respectively). CONCLUSIONS Measuring the preoperative volume of the injured orbit is sufficient data for an indication because reconstruction depends primarily on the correlation between the volume and enophthalmos. The findings from this study showed that preoperative orbital volumetry using computed tomography evaluated enophthalmos and provide data to assist orbital floor reconstruction.

Indexed as

EnophthalmosOrbital FracturesPlastic Surgery ProceduresHumansOrbitPolyestersRetrospective StudiesSerbiaTitaniumPolyesterspoly(lactide)Titanium

Identifiers

PMID36840343
PMCPMC9976474
OpenAlexW4317401641

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked