Evidence map›Paper›PMID 36837096›Full record

ArticleMaterials (Basel, Switzerland)2023

Design and Performance Evaluation of a Novel Spiral Head-Stem Trunnion for Hip Implants Using Finite Element Analysis.

Md Mohiuddin Soliman, Muhammad E H Chowdhury, Mohammad Tariqul Islam, Farayi Musharavati, Sakib Mahmud, Muhammad Hafizh, Mohamed Arselene Ayari, Amith Khandakar, Mohammad Kaosar Alam, Erfan Zal Nezhad

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 3 countries.

Md Mohiuddin SolimanDepartment of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.ORCID 0000-0002-0268-9978
Muhammad E H ChowdhuryDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0003-0744-8206
Mohammad Tariqul IslamCentre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Selangor, Malaysia.ORCID 0000-0002-4929-3209
Farayi MusharavatiDepartment of Mechanical & Industrial Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0003-0489-0090
Sakib MahmudDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0002-4599-2192
Muhammad HafizhDepartment of Mechanical & Industrial Engineering, Qatar University, Doha 2713, Qatar.
Mohamed Arselene AyariDepartment of Civil and Architectural Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0002-8663-886X
Amith KhandakarDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0001-7068-9112
Mohammad Kaosar AlamDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.
Erfan Zal NezhadDepartment of Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA.
Qatar University · QANational University of Malaysia · MYThe University of Texas at San Antonio · US

Funding

Qatar National Research Fund NPRP11S-0102-180178
6 · The paper itself

Abstract

With an expectation of an increased number of revision surgeries and patients receiving orthopedic implants in the coming years, the focus of joint replacement research needs to be on improving the mechanical properties of implants. Head-stem trunnion fixation provides superior load support and implant stability. Fretting wear is formed at the trunnion because of the dynamic load activities of patients, and this eventually causes the total hip implant system to fail. To optimize the design, multiple experiments with various trunnion geometries have been performed by researchers to examine the wear rate and associated mechanical performance characteristics of the existing head-stem trunnion. The objective of this work is to quantify and evaluate the performance parameters of smooth and novel spiral head-stem trunnion types under dynamic loading situations. This study proposes a finite element method for estimating head-stem trunnion performance characteristics, namely contact pressure and sliding distance, for both trunnion types under walking and jogging dynamic loading conditions. The wear rate for both trunnion types was computed using the Archard wear model for a standard number of gait cycles. The experimental results indicated that the spiral trunnion with a uniform contact pressure distribution achieved more fixation than the smooth trunnion. However, the average contact pressure distribution was nearly the same for both trunnion types. The maximum and average sliding distances were both shorter for the spiral trunnion; hence, the summed sliding distance was approximately 10% shorter for spiral trunnions than that of the smooth trunnion over a complete gait cycle. Owing to a lower sliding ability, hip implants with spiral trunnions achieved more stability than those with smooth trunnions. The anticipated wear rate for spiral trunnions was 0.039 mm

Indexed as

contact pressuresliding distancespiral head-stem trunnionwear rate

Identifiers

PMID36837096
PMCPMC9962303
OpenAlexW4319983025

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked