Evidence map›Paper›PMID 36836841›Full record

ArticleLife (Basel, Switzerland)2023

In Vitro Investigation of the Fixation Performance of a Bioabsorbable Magnesium ACL Interference Screw Compared to a Conventional Interference Screw.

Nad Siroros, Ricarda Merfort, Yu Liu, Maximilian Praster, Frank Hildebrand, Roman Michalik, Jörg Eschweiler

Open access · goldAbstract read
In one paragraph

Article in Life (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. [Research progress on the role and mechanism of magnesium element and magnesium materials in tendon-bone interface healing].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Review
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Nad SirorosDepartment of Orthopaedics, Trauma, and Reconstructive Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany.ORCID 0000-0001-7289-1699
Ricarda MerfortDepartment of Orthopaedics, Trauma, and Reconstructive Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany.
Yu LiuDepartment of Orthopaedics, Trauma, and Reconstructive Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany.
Maximilian PrasterDepartment of Orthopaedics, Trauma, and Reconstructive Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany.
Frank HildebrandDepartment of Orthopaedics, Trauma, and Reconstructive Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany.
Roman MichalikDepartment of Orthopaedics, Trauma, and Reconstructive Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany.ORCID 0000-0002-9431-0637
Jörg EschweilerDepartment of Orthopaedics, Trauma, and Reconstructive Surgery, University Hospital RWTH Aachen, 52074 Aachen, Germany.
RWTH Aachen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An anterior cruciate ligament (ACL) reconstruction is a common treatment for patients with ACL rupture that aims to regain pre-injury knee stability and kinematics. During the ACL reconstruction, one method to fix the graft is the use of an interference screw (IS). The IS should provide initial stability and secure the graft during the healing period. In recent years, magnesium has emerged as an alternative material to permanent metal and polymer ISs. In addition, differences in designs, such as the shape of the IS, can influence the fixation performance of the IS. Therefore, in this biomechanical experiment, two different screw designs with two ligament materials were compared in an insertion and a pull-out test at a rate of 1 mm/s. The screw designs were a conventional polymer screw and a magnesium screw. Porcine tendon and nylon rope were used as ligament materials. All tests were performed in polyurethane foam blocks with 15 PCF density (Synbone AG, Switzerland). As a result, both screw designs required an insertion torque of less than 3 Nm. There was a significant difference between the porcine and nylon rope in pull-out tests for each screw design. The magnesium screw had the highest pull-out force at 412.14 ± 50.00 N for porcine tendon and 707.38 ± 21.81 N for nylon rope. There were no significant differences in tunnel widening (narrow-wide ratio) between each ligament material. The magnesium screw showed the lowest narrow-wide tunnel ratio, implying a better ability to compress the graft to the tunnel. In conclusion, a more optimized magnesium IS design resulted in better graft fixation and an improved ACL reconstruction outcome.

Indexed as

ACL reconstructionbioabsorbablebiomechanicsinterference screwmagnesium

Identifiers

PMID36836841
PMCPMC9959181
OpenAlexW4319982012

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.