Evidence map›Paper›PMID 36836741›Full record

ArticleLife (Basel, Switzerland)2023

Assessment of Intra-Abdominal Pressure with a Novel Continuous Bladder Pressure Monitor-A Clinical Validation Study.

Liat Iacubovici, Dana Karol, Yuval Baar, Avi Beri, Haim Herzberg, Shiri Zarour, Or Goren, Barak Cohen

Open access · goldAbstract read
In one paragraph

Article in Life (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 2 countries.

Liat IacuboviciDivision of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel.
Dana KarolDivision of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel.
Yuval BaarDivision of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel.
Avi BeriUrology Department, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel.
Haim HerzbergUrology Department, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel.
Shiri ZarourDivision of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel.
Or GorenDivision of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel.
Barak CohenDivision of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Tel-Aviv 6423906, Israel.
Tel Aviv University · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIntra-abdominal hypertension and the resulting abdominal compartment syndrome are serious complications of severely ill patients. Diagnosis requires an intra-abdominal pressure (IAP) measurement, which is currently cumbersome and underused. We aimed to test the accuracy of a novel continuous IAP monitor.

methodsAdults having laparoscopic surgery and requiring urinary catheter intra-operatively were recruited to this single-arm validation study. IAP measurements using the novel monitor and a gold-standard foley manometer were compared. After anesthesia induction, a pneumoperitoneum was induced through a laparoscopic insufflator, and five randomly pre-defined pressures (between 5 and 25 mmHg) were achieved and simultaneously measured via both methods in each participant. Measurements were compared using Bland-Altman analysis.

resultsIn total, 29 participants completed the study and provided 144 distinct pairs of pressure measurements that were analyzed. A positive correlation between the two methods was found (R

conclusionsContinuous IAP measurements using the novel monitor performed well in the clinical setup of controlled intra-abdominal hypertension across the evaluated range of pressures. Further studies should expand the range to more pathological values.

Indexed as

abdominal compartment syndromefoley manometerintra-abdominal hypertensionintra-abdominal pressure monitoring

Identifiers

PMID36836741
PMCPMC9967253
OpenAlexW4318612043

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.