Evidence map›Paper›PMID 36831938›Full record

ArticleBiosensors2023

Real-Time Ellipsometric Surface Plasmon Resonance Sensor Using Polarization Camera May Provide the Ultimate Detection Limit.

Nipun Vashistha, Marwan J Abuleil, Anand M Shrivastav, Aabha Bajaj, Ibrahim Abdulhalim

Abstract read
In one paragraph

Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nipun VashisthaDepartment of Electro-Optic Engineering, Ilse-Katz Institute for Nanoscale Science and Technology, Ben Gurion University, Beer Sheva 84105, Israel.ORCID 0000-0002-5423-6364
Marwan J AbuleilDepartment of Electro-Optic Engineering, Ilse-Katz Institute for Nanoscale Science and Technology, Ben Gurion University, Beer Sheva 84105, Israel.ORCID 0000-0003-2355-624X
Anand M ShrivastavDepartment of Electro-Optic Engineering, Ilse-Katz Institute for Nanoscale Science and Technology, Ben Gurion University, Beer Sheva 84105, Israel.ORCID 0000-0002-3257-2818
Aabha BajajDepartment of Electro-Optic Engineering, Ilse-Katz Institute for Nanoscale Science and Technology, Ben Gurion University, Beer Sheva 84105, Israel.
Ibrahim AbdulhalimDepartment of Electro-Optic Engineering, Ilse-Katz Institute for Nanoscale Science and Technology, Ben Gurion University, Beer Sheva 84105, Israel.ORCID 0000-0002-1474-5412

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ellipsometric Surface Plasmon Resonance (SPR) sensors are known for their relatively simple optical configuration compared to interferometric and optical heterodyne phase interrogation techniques. However, most of the previously explored ellipsometric SPR sensors based on intensity measurements are limited by their real-time applications because phase or polarization shifts are conducted serially. Here we present an ellipsometric SPR sensor based on a Kretschmann-Raether (KR) diverging beam configuration and a pixelated microgrid polarization camera. The proposed methodology has the advantage of real-time and higher precision sensing applications. The short-term stability of the measurement using the ellipsometric parameters tanψ and cos(Δ) is found to be superior over direct SPR or intensity measurements, particularly with fluctuating sources such as laser diodes. Refractive index and dynamic change measurements in real-time are presented together with Bovine Serum Albumin (BSA)-anti-BSA antibody binding to demonstrate the potential of the developed sensor for biological sensing applications with a resolution of sub-nM and down to pM with additional optimization. The analysis shows that this approach may provide the ultimate detection limit for SPR sensors.

Indexed as

Biosensing TechniquesSurface Plasmon ResonanceLimit of DetectionRefractometrySerum Albumin, BovineSerum Albumin, Bovineellipsometryphase measurementpolarization camerasurface plasmons

Identifiers

PMID36831938
PMCPMC9953146

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.