Evidence map›Paper›PMID 36831106›Full record

ArticleBiomedicines2023

The Effect of a Digital Manufacturing Technique, Preparation Taper, and Finish Line Design on the Marginal Fit of Temporary Molar Crowns: An In-Vitro Study.

Maryam H Mugri, Harisha Dewan, Mohammed E Sayed, Fawzia Ibraheem Shaabi, Hanan Ibrahim Hakami, Hossam F Jokhadar, Nasser M Alqahtani, Ahid Amer Alshahrani, Abdullah S Alabdullah, Abdullah Hasan Alshehri and 5 more

Open access · goldAbstract read
In one paragraph

Article in Biomedicines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.5field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. AnJournal of Indian Prosthodontic Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 4 institutions in 1 country.

Maryam H MugriDepartment of Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.ORCID 0000-0002-5613-9760
Harisha DewanDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.ORCID 0000-0002-2294-4710
Mohammed E SayedDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.ORCID 0000-0001-8667-8987
Fawzia Ibraheem ShaabiDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.
Hanan Ibrahim HakamiPrimary Care Administration, Ministry of Health, Jazan 45142, Saudi Arabia.
Hossam F JokhadarDepartment of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
Nasser M AlqahtaniDepartment of Prosthetic Dental Sciences, College of Dentistry, King Khalid University, Abha 61413, Saudi Arabia.
Ahid Amer AlshahraniDepartment of Dental Technology, Applied Medical Sciences College, King Khalid University, Abha 61413, Saudi Arabia.ORCID 0000-0002-8496-184X
Abdullah S AlabdullahKing Faisal Medical City, Ministry of Health, Abha 62586, Saudi Arabia.
Abdullah Hasan AlshehriDepartment of Prosthetic Dental Sciences, College of Dentistry, King Khalid University, Abha 61413, Saudi Arabia.ORCID 0000-0003-1097-5218
Mohammed Hussain Dafer Al WadeiDepartment of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha 61413, Saudi Arabia.
Fatimah Yahya ArifPrivate Practice, Jazan University, Jazan 45142, Saudi Arabia.
Ebtihag H AdawiPrimary Care Administration, Ministry of Health, Jazan 45142, Saudi Arabia.
Bandar M A Al-MakramaniDepartment of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.ORCID 0000-0003-0983-7846
Hitesh ChohanDepartment of Restorative Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.
Jazan University · SAKing Khalid University · SAMinistry of Health · SAKing Abdulaziz University · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study is to investigate the combined effect of a digital manufacturing technique (subtractive vs. additive), preparation taper (10° vs. 20° TOC), and finish line (chamfer vs. shoulder) on the marginal adaptation of temporary crowns following cementation with a compatible temporary cement. Four mandibular first molar typodont teeth were prepared for full coverage crowns with standard 4 mm preparation height as follows: 10° TOC with the chamfer finish line, 10° TOC with the shoulder finish line, 20° TOC with the chamfer finish line and 20° TOC with the shoulder finish line. Each of the four preparation designs were subdivided into two subgroups to receive CAD/CAM milled and 3D-printed crowns (

Indexed as

3D printedCAD/CAM milledfinish linemarginal gapspreparation tapertemporary crowns

Identifiers

PMID36831106
PMCPMC9953521
OpenAlexW4320916915

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.