Evidence map›Paper›PMID 36829762›Full record

ArticleBioengineering (Basel, Switzerland)2023

Development of a Hip Joint Socket by Finite-Element-Based Analysis for Mechanical Assessment.

Ana Karen González, Juvenal Rodríguez-Reséndiz, José Eli Eduardo Gonzalez-Durán, Juan Manuel Olivares Ramírez, Adyr A Estévez-Bén

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ana Karen GonzálezEngineering Faculty, Universidad Autónoma de Querétaro, Querétaro 76010, Mexico.ORCID 0000-0002-9540-0570
Juvenal Rodríguez-ReséndizEngineering Faculty, Universidad Autónoma de Querétaro, Querétaro 76010, Mexico.ORCID 0000-0001-8598-5600
José Eli Eduardo Gonzalez-DuránElectronics Engineering Department, Instituto Tecnológico Superior del Sur de Guanajuato, Guanajuato 38980, Mexico.ORCID 0000-0002-6897-9716
Juan Manuel Olivares RamírezDepartment of Renewable Energy, Universidad Tecnológica de San Juan del Río, Querétaro 76800, Mexico.ORCID 0000-0003-2427-6936
Adyr A Estévez-BénEngineering Faculty, Universidad Autónoma de Querétaro, Querétaro 76010, Mexico.ORCID 0000-0002-7613-7463

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This article evaluates a hip joint socket design by finite element method (FEM). The study was based on the needs and characteristics of a patient with an oncological amputation; however, the solution and the presented method may be generalized for patients with similar conditions. The research aimed to solve a generalized problem, taking a typical case from the study area as a reference. Data were collected on the use of the current improving prosthesis-specifically in interaction with its socket-to obtain information on the new approach design: this step constituted the work's starting point, where the problems to be solved in conventional designs were revealed. Currently, the development of this type of support does not consider the functionality and comfort of the patient. Research has reported that 58% of patients with sockets have rejected their use, because they do not fit comfortably and functionally; therefore, patients' low acceptance or rejection of the use of the prosthesis socket has been documented. In this study, different designs were evaluated, based on the FEM as scientific support for the results obtained, for the development of a new ergonomic fit with a 60% increase in patient compliance, that had correct gait performance when correcting postures, improved fit-user interaction, and that presented an esthetic fit that met the usability factor. The validation of the results was carried out through the physical construction of the prototype. The research showed how the finite element method improved the design, analyzing the structural behavioral, and that it could reduce cost and time instead of generating several prototypes.

Indexed as

computational-modeling-based designergonomic designfinite element analysiship disarticulationjoint biomechanicsmechanical designprosthesis

Identifiers

PMID36829762
PMCPMC9952638

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.