Evidence map›Paper›PMID 36829703›Full record

ArticleBioengineering (Basel, Switzerland)2023

Cascade of Denoising and Mapping Neural Networks for MRI R2* Relaxometry of Iron-Loaded Liver.

Qiqi Lu, Changqing Wang, Zifeng Lian, Xinyuan Zhang, Wei Yang, Qianjin Feng, Yanqiu Feng

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Qiqi LuSchool of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China.ORCID 0000-0001-6066-0690
Changqing WangSchool of Biomedical Engineering, Anhui Medical University, Hefei 230000, China.
Zifeng LianSchool of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China.
Xinyuan ZhangSchool of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China.
Wei YangSchool of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China.
Qianjin FengSchool of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China.
Yanqiu FengSchool of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China.

Funding

Anhui Provincial Natural Science Foundation 2008085QH425Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence Fund 2019022Key-Area Research and Development Program of Guangdong Province 2018B030340001National Natural Science Foundation of China 61971214National Natural Science Foundation of China 62001005National Natural Science Foundation of China 81871349Natural Science Foundation of Guangdong Province 2019A1515011513Science and Technology Program of Guangdong 2018B030333001
6 · The paper itself

Abstract

MRI of effective transverse relaxation rate (R2*) measurement is a reliable method for liver iron concentration quantification. However, R2* mapping can be degraded by noise, especially in the case of iron overload. This study aimed to develop a deep learning method for MRI R2* relaxometry of an iron-loaded liver using a two-stage cascaded neural network. The proposed method, named CadamNet, combines two convolutional neural networks separately designed for image denoising and parameter mapping into a cascade framework, and the physics-based R2* decay model was incorporated in training the mapping network to enforce data consistency further. CadamNet was trained using simulated liver data with Rician noise, which was constructed from clinical liver data. The performance of CadamNet was quantitatively evaluated on simulated data with varying noise levels as well as clinical liver data and compared with the single-stage parameter mapping network (MappingNet) and two conventional model-based R2* mapping methods. CadamNet consistently achieved high-quality R2* maps and outperformed MappingNet at varying noise levels. Compared with conventional R2* mapping methods, CadamNet yielded R2* maps with lower errors, higher quality, and substantially increased efficiency. In conclusion, the proposed CadamNet enables accurate and efficient iron-loaded liver R2* mapping, especially in the presence of severe noise.

Indexed as

cascade networkconvolutional neural networkliver iron overloadMR relaxometryR2* mapping

Identifiers

PMID36829703
PMCPMC9952355

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.