Evidence map›Paper›PMID 36829632›Full record

ArticleBioengineering (Basel, Switzerland)2023

Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set.

Mateng Bai, Da Li, Kaiyao Xu, Shuyu Ouyang, Ding Yuan, Tinghui Zheng

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mateng BaiDepartment of Applied Mechanics, Sichuan University, No. 24 South Section 1, Chengdu 610065, China.
Da LiDepartment of Applied Mechanics, Sichuan University, No. 24 South Section 1, Chengdu 610065, China.
Kaiyao XuDepartment of Applied Mechanics, Sichuan University, No. 24 South Section 1, Chengdu 610065, China.
Shuyu OuyangDepartment of Biomedical Engineering, Sichuan University, Chengdu 610065, China.
Ding YuanDivision of Vascular Surgery, Department of General Surgery, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu 610041, China.
Tinghui ZhengDepartment of Applied Mechanics, Sichuan University, No. 24 South Section 1, Chengdu 610065, China.ORCID 0000-0002-0597-3245

Funding

National Natural Science Foundation of China 12072214National Natural Science Foundation of China 1802253National Natural Science Foundation of China 81770471Sichuan Science and Technology Department Support plan 2018YYJCSichuan Science and Technology Department Support plan 2019YJ0026
6 · The paper itself

Abstract

objectivesPost-operative stent morphology of aortic dissection patients is important for performing clinical diagnosis and prognostic assessment. However, stent morphologies still need to be manually measured, which is a process prone to errors, high time consumption and difficulty in exploiting inter-data associations. Herein, we propose a method based on the stepwise combination of basic, non-divisible data sets to quickly obtain morphological parameters with high accuracy.

methodsWe performed the 3D reconstruction of 109 post-operative follow-up CT image data from 26 patients using mimics software. By extracting the spatial locations of the basic morphological observation points on the stent, we defined a basic and non-reducible set of observation points. Further, we implemented a fully automatic stent segmentation and an observation point extraction algorithm. We analyzed the stability and accuracy of the algorithms on a test set containing 8 cases and 408 points. Based on this dataset, we calculated three morphological parameters of different complexity for the different spatial structural features exhibited by the stent. Finally, we compared the two measurement schemes in four aspects: data variability, data stability, statistical process complexity and algorithmic error.

resultsThe statistical results of the two methods on two low-complexity morphological parameters (spatial position of stent end and vascular stent end-slip volume) show good agreement (

conclusionsThe proposed method can significantly reduce the statistical observation time and information processing cost compared to the traditional morphological observation methods. Moreover, when new morphological parameters are required, one can quickly and accurately obtain the target parameters by new "combinatorial functions." Iterative modification of the data set itself is avoided.

Indexed as

aortic dissectioncompleteness datasetmorphological parametersstatistical time complexitythoracic aortic stent

Identifiers

PMID36829632
PMCPMC9951888

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.