Evidence map›Paper›PMID 36828989›Full record

ArticleScientific reports2023

A new patient-specific overformed anatomical implant design method to reconstruct dysplastic femur trochlea.

Yetkin Öztürk, Murat Ayazoğlu, Çağrı Öztürk, Atakan Arabacı, Nuri Solak, Serhat Özsoy

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Yetkin ÖztürkMolecular Biology and Genetics Department, Science and Literature Faculty, Istanbul Technical University, Maslak, 34469, Istanbul, Turkey. yetkinozturk@itu.edu.tr.ORCID 0000-0002-9524-5654
Murat AyazoğluFaculty of Manufacturing Engineering, Istanbul Technical University, Gumussuyu, 34437, Istanbul, Turkey.ORCID 0000-0001-8704-7829
Çağrı ÖztürkMetallurgical and Materials Engineering Department, Chemical, and Metallurgical Engineering Faculty, Istanbul Technical University, Maslak, 34469, Istanbul, Turkey.ORCID 0000-0001-8853-0417
Atakan ArabacıMetallurgical and Materials Engineering Department, Chemical, and Metallurgical Engineering Faculty, Istanbul Technical University, Maslak, 34469, Istanbul, Turkey.ORCID 0000-0002-2319-5301
Nuri SolakMetallurgical and Materials Engineering Department, Chemical, and Metallurgical Engineering Faculty, Istanbul Technical University, Maslak, 34469, Istanbul, Turkey.ORCID 0000-0002-6493-7711
Serhat ÖzsoySurgery Department, Veterinary Faculty, Istanbul University-Cerrahpasa, Buyukcekmece, 34500, Istanbul, Turkey.ORCID 0000-0003-0988-7691
Istanbul Technical University · TRIstanbul University-Cerrahpaşa · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patellar luxation with condylar defect is a challenging situation for reconstruction in humans. Patella reluxation, cartilage damage and pain are the most common complications. This study aims to present a new patient specific method of overformed implant design and clinical implantation that prevents luxation of patella without damaging the cartilage in a dog. Design processes are Computer Tomography, Computer Assisted Design, rapid prototyping of the bone replica, creation of the implant with surgeon's haptic knowledge on the bone replica, 3D printing of the implant and clinical application. The implant was fully seated on the bone. Patella reluxation or implant-related bone problem was not observed 80 days after the operation. However, before the implant application, there were soft tissue problems due to previous surgeries. Three-point bending test and finite element analysis were performed to determine the biomechanical safety of the implant. The stress acting on the implant was below the biomechanical limits of the implant. More cases with long-term follow-up are needed to confirm the success of this method in patellar luxation. Compared with trochlear sulcoplasty and total knee replacement, there was no cartilage damage done by surgeons with this method, and the implant keeps the patella functionally in sulcus. This is a promising multidisciplinary method that can be applied to any part of the bone and can solve some orthopaedic problems with surgeon's haptic knowledge.

Indexed as

Arthroplasty, Replacement, KneePatellar DislocationAnimalsCartilageDogsFemurHumansPatella

Identifiers

PMID36828989
PMCPMC9958018
OpenAlexW4321785916

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.