ArticleScientific reports2023
Reorientation methodology for reproducible head posture in serial cone beam computed tomography images.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Methodology for the correction of a CBCT volume from the skull to the natural head position.MethodsX · 2024Article
- Gender differences in ethmoid sinus morphology_ 3D reconstruction of computed tomographic images.BMC medical imaging · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Low dose and accessibility have increased the application of cone beam computed tomography (CBCT). Often serial images are captured for patients to diagnose and plan treatment in the craniofacial region. However, CBCT images are highly variable and lack harmonious reproduction, especially in the head's orientation. Though user-defined orientation methods have been suggested, the reproducibility remains controversial. Here, we propose a landmark-free reorientation methodology based on principal component analysis (PCA) for harmonious orientation of serially captured CBCTs. We analyzed three serial CBCT scans collected for 29 individuals who underwent orthognathic surgery. We first defined a region of interest with the proposed protocol by combining 2D rendering and 3D convex hull method, and identified an intermediary arrangement point. PCA identified the y-axis (anterioposterior) followed by the secondary x-axis (transverse). Finally, by defining the perpendicular z-axis, a new global orientation was assigned. The goodness of alignment (Hausdorff distance) showed a marked improvement (> 50%). Furthermore, we clustered cases based on clinical asymmetry and validated that the protocol was unaffected by the severity of the skeletal deformity. Therefore, it could be suggested that integrating the proposed algorithm as the preliminary step in CBCT evaluation will address a fundamental step towards harmonizing the craniofacial imaging records.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.