SynthesisPloS one2023
Cemented vs Uncemented hemiarthroplasties for femoral neck fractures: An overlapping systematic review and evidence appraisal.
Synthesis in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A meta-analysis comparing the effects of cemented and uncemented prostheses on wound infection and pain in patients with femoral neck fractures.International wound journal · 2023Pooled it
- Long-term outcomes of cemented compared to uncemented femoral stems in total hip arthroplasty for displaced femoral neck fractures in elderly patients.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025Trial
- A Discrepancy Between Evidence and Practice: Underuse of Cemented Hemiarthroplasty for Femoral Neck Fractures and Its Association With Surgeon Training Background.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026Article
- [Surgical treatment variation of displaced femoral neck fractures in certified centers for geriatric trauma DGU® and arthroplasty centers in Germany].Unfallchirurgie (Heidelberg, Germany) · 2025Article
- Cementing Without Trialing is Safe and Efficient for Hip Hemiarthroplasty.Arthroplasty today · 2025Article
- Use of Cemented Hemiarthroplasty for Femoral Neck Fractures.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2025Review
- Is Modular Prosthesis Superior to Monoblock Variant in Hemiarthroplasty for Fracture Neck of Femur?Journal of orthopaedic case reports · 2024Article
- Several methods for assessing research waste in reviews with a systematic search: a scoping review.PeerJ · 2024Article
- Risk factors for templating mismatch of uncemented stems in bipolar hemiarthroplasty for femoral neck fracture.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe purpose of our study is to assess the methodology of overlapping systematic reviews related to cemented vs uncemented hip hemiarthroplasties for the treatment of femoral neck fractures to find the study with the best evidence. Also, we assess the gaps in methodology and information to help with direction of future studies.
methodsA systematic search was conducted in September 2022 using Pubmed, Embase, and Cochrane Library. Clinical outcome data and characteristics of each study were extracted to see which treatment had better favorability. The outcomes and characteristics extracted from each study includes, first author, search date, publication journal and date, number of studies included, databases, level of evidence, software used, subgroup analyses that were conducted, and heterogeneity with the use of I2 statistics Methodological quality information was extracted from each study using four different methodologic scores (Oxford Levels of Evidence; Assessment of Multiple Systematic Reviews (AMSTAR); Quality of reporting of meta-analyses (QUROM); Oxman and Guyatt. After that, the Jadad decision algorithm was used to identify which studies in our sample contained the best available evidence. Finally, overlap of each systematic review was assessed using Corrected Covered Area (CCA) to look at redundancy and research waste among the systematic reviews published on the topic.
resultsAfter screening, 12 studies were included in our sample. For the Oxford Levels of Evidence, we found that all the studies were Level I evidence. For the QUORUM assessment, we had 1 study with the highest score of 18. Additionally, we did the Oxman and Guyatt assessment, where we found 4 studies with a maximum score of 6. Finally, we did an AMSTAR assessment and found 2 studies with a score of 9. After conducting the methodological scores; the authors determined that Li. L et al 2021 had the highest quality. In addition, it was found that the CCA found among the primary studies in each systematic review calculated to .22. Any CCA above .15 is considered "very high overlap".
conclusionsThe best available evidence suggests that Cemented HAs are better at preventing Prosthesis-related complications. Conversely, the best evidence also suggests that Cemented HA also results in longer operative time and increased intraoperative blood loss. When conducting future systematic reviews related to the topic, we ask that authors restrict conducting another systematic review until new evidence emerges so as not to confuse the clinical decision-making of physicians.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.