Evidence map›Paper›PMID 36825679›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2023

Ultrathin, Soft, Bioresorbable Organic Electrochemical Transistors for Transient Spatiotemporal Mapping of Brain Activity.

Mengge Wu, Kuanming Yao, Ningge Huang, Hu Li, Jingkun Zhou, Rui Shi, Jiyu Li, Xingcan Huang, Jian Li, Huiling Jia and 9 more

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Smart Nanotechnologies for Multimodal Neuromodulation and Brain Interfacing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  6. Ionic-Bionic Interfaces: Advancing Iontronic Strategies for Bioelectronic Sensing and Therapy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  7. Review
  8. Article
  9. Organic Electrochemical Transistors in Tissue-Interfaced Bioelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  10. Article
  11. Article
  12. Advances in Symbiotic Bioabsorbable Devices.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  13. An organic electrochemical neuron for a neuromorphic perception system.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
  14. Review
  15. Recent Progress of Soft and Bioactive Materials in Flexible Bioelectronics.Cyborg and bionic systems (Washington, D.C.) · 2025
    Review
  16. Article
  17. Article
  18. Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

19 authors.

Mengge WuState Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, 610054, P. R. China.ORCID 0000-0002-8116-5717
Kuanming YaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Ningge HuangShanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of Optoelectronics, Fudan University, Shanghai, 200433, P. R. China.
Hu LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Jingkun ZhouDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Rui ShiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Jiyu LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Xingcan HuangDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Jian LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Huiling JiaDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Zhan GaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Tsz Hung WongDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Dengfeng LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Sihui HouState Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, 610054, P. R. China.
Yiming LiuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.
Shiming ZhangDepartment of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, SAR, P. R. China.
Enming SongShanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of Optoelectronics, Fudan University, Shanghai, 200433, P. R. China.
Junsheng YuState Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, 610054, P. R. China.
Xinge YuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong, P. R. China.ORCID 0000-0003-0522-1171

Funding

City University of Hong Kong 9240074City University of Hong Kong 9680322Lingang Laboratory LG-QS-202202-02National Natural Science Foundation of China 61421002National Natural Science Foundation of China 62204057National Natural Science Foundation of China 62275041National Natural Science Foundation of China U21A20492Shanghai Municipal Science and Technology Major Project 2018SHZDZX01STI 2030-Major Projects 2022ZD0209900the Sichuan Province Key Laboratory of Display Science and Technology, and Qiantang Science & Technology Innovation Centerthe Sichuan Science and Technology Program 2022YFG0012the Sichuan Science and Technology Program 2022YFG0013the Sichuan Science and Technology Program 2022YFH0081
6 · The paper itself

Abstract

A critical challenge lies in the development of the next-generation neural interface, in mechanically tissue-compatible fashion, that offer accurate, transient recording electrophysiological (EP) information and autonomous degradation after stable operation. Here, an ultrathin, lightweight, soft and multichannel neural interface is presented based on organic-electrochemical-transistor-(OECT)-based network, with capabilities of continuous high-fidelity mapping of neural signals and biosafety active degrading after performing functions. Such platform yields a high spatiotemporal resolution of 1.42 ms and 20 µm, with signal-to-noise ratio up to ≈37 dB. The implantable OECT arrays can well establish stable functional neural interfaces, designed as fully biodegradable electronic platforms in vivo. Demonstrated applications of such OECT implants include real-time monitoring of electrical activities from the cortical surface of rats under various conditions (e.g., narcosis, epileptic seizure, and electric stimuli) and electrocorticography mapping from 100 channels. This technology offers general applicability in neural interfaces, with great potential utility in treatment/diagnosis of neurological disorders.

Indexed as

Absorbable ImplantsElectrophysiological PhenomenaAnimalsBrainElectronicsRatsbioresorbable materialsmultichannel electrophysiology mappingneural interfacesorganic electrochemical transistortransient electronics

Identifiers

PMID36825679
PMCPMC10190644

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.