Evidence map›Paper›PMID 36819471›Full record

ArticleJournal of contemporary brachytherapy2022

Dual-source strength seed loading for eye plaque brachytherapy using eye physics eye plaques: A feasibility study.

Sheridan G Meltsner, David G Kirsch, Miguel A Materin, Yongbok Kim, Yang Sheng, Oana Craciunescu

Open access · goldAbstract read
In one paragraph

Article in Journal of contemporary brachytherapy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Innovations in brachytherapy.Taiwan journal of ophthalmology
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Sheridan G MeltsnerDepartment of Radiation Oncology, Duke University, Durham, North Carolina, USA.
David G KirschDepartment of Radiation Oncology, Duke University, Durham, North Carolina, USA.
Miguel A MaterinDepartments of Ophthalmology, Duke University, Durham, North Carolina, USA.
Yongbok KimDepartment of Radiation Oncology, Duke University, Durham, North Carolina, USA.
Yang ShengDepartment of Radiation Oncology, Duke University, Durham, North Carolina, USA.
Oana CraciunescuDepartment of Radiation Oncology, Duke University, Durham, North Carolina, USA.
Duke University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study quantifies the dosimetric impact of incorporating two iodine-125 ( Material and methods: Plaque Simulator was used to retrospectively plan 15 clinical cases of three types: (1) Shallow tumors (< 5.5 mm) with large base dimensions (range, 16-19 mm); (2) Tumors near the optic nerve planned with notched plaques; and (3) Very shallow (< 3.0 mm) tumors with moderate base dimensions (range, 13.5-15.5 mm) planned with larger plaques than requested by the ocular oncologist. Circular plaques were planned with outer ring sources twice the source strength of inner sources, and notched plaques with the six seeds closest to the notch at twice the source strength. Results: In cases of type (1), the dual-source strength plan decreased prescription depth, and doses to critical structures were lower: inner sclera -25% ±2%, optic disc -7% ±3%, and fovea -6% ±3%. In four out of five cases of type (2), the dual-source strength plan decreased prescription depth, and dose to inner sclera was lower (-22% ±5%), while dose to optic disc (17% ±7%) and fovea (20% ±12%) increased. In cases of type (3), a smaller dual-source strength plaque was used, and scleral dose was lower (-45% ±3%), whereas dose to optic disc (1% ±14%) and fovea (5% ±5%) increased. Conclusions: Dual-source strength loading as described in this study can be used to cover tumor margins and decrease dose to sclera, and therefore the adjacent retina, but can either decrease or increase radiation dose to optic disc and fovea depending on location and size of the tumor. This technique may allow the use of a smaller plaque, if requested by the ocular oncologist. Clinical determination to use this technique should be performed on an individual basis, and additional QA steps are required. Integrating the use of volumetric imaging may be warranted.

Indexed as

Eye Physics eye plaqueseye plaque treatment planningplaque brachytherapyPlaque Simulator treatment planning systemuveal melanoma

Identifiers

PMID36819471
PMCPMC9924146
OpenAlexW4316652085

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.