The new fast kilovoltage-switching dual-energy computed tomography for measuring bone mineral density.

Mingyue Wang, Yan Wu, Yue Zhou, Junqiang Dong, Ping Hou, Jianbo Gao

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.8field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Harnessing dual-energy CT for glycogen quantification: a phantom analysis.Quantitative imaging in medicine and surgery · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Mingyue WangDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Yan WuDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Yue ZhouDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Junqiang DongDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Ping HouDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Jianbo GaoDepartment of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
First Affiliated Hospital of Zhengzhou University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The update in technology may impact the accuracy in measuring bone mineral density (BMD). However, the application of the new fast kilovoltage (kV)-switching dual-energy computed tomography (DECT) for BMD measurement has not yet been reported. This study aimed to examine the accuracy and precision of the new fast kV-switching DECT in measuring BMD and to evaluate its applicability in clinical BMD measurement. Methods: Forty sets of the new fast kV-switching DECT scans and one quantitative computed tomography (QCT) scan were performed on the European Spine Phantom. Their relative errors and relative standard deviations were compared. A retrospective analysis was performed on patients who underwent chest plain DECT and abdominal monoenergetic plain CT at the same time. The relationship between hydroxyapatite-water and hydroxyapatite-fat measured using DECT and BMD measured using QCT was analyzed by multivariate regression analysis. Results: The relative errors of the new fast kV-switching DECT with low tube speeds (0.8 and 1.0 s/r) were all less than 6% and were less than those of QCT, except for those at 515 mA. The relative standard deviation values with high tube rotation speeds (0.5 and 0.6 s/r) were higher than those with low tube speeds (0.8 and 1.0 s/r) under most tube current conditions. The new fast kV-switching DECT-derived BMD values corrected by multiple linear regression (predicted hydroxyapatite) were significantly positively correlated with the QCT-based BMD values (R Conclusions: Results of the phantom measurements indicated that the new fast kV-switching DECT could measure BMD with relatively high accuracy and precision. The results of a subsequent clinical

Indexed as

accuracyBone densitydual-energy computed tomography (DECT)phantomsquantitative computed tomography (QCT)

Identifiers

PMID36819284
PMCPMC9929404
OpenAlexW4313642209

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.