ArticleMultibody system dynamics2023
A novel motion-reconstruction method for inertial sensors with constraints.
Article in Multibody system dynamics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 13 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Motion reconstruction for rigid bodies and rigid-body frames using data from inertial measurement units (IMUs) is a challenging task. Position and orientation determination by means of IMUs is erroneous, as deterministic and stochastic errors accumulate over time. The former of which errors can be minimized by standard calibration approaches, however, sensor calibration with respect to a common reference coordinate system to correct misalignment, has not been fully addressed yet. The latter stochastic errors are mostly reduced using sensor fusion. In this paper, we present a novel motion-reconstruction method utilizing optimization to correct measured IMU data by means of correction polynomials to minimize the deviation of motion constraints. In addition, we perform gyrometer and accelerometer calibration with an industrial manipulator to address deterministic IMU errors, especially misalignment. To evaluate the performance of the novel methods, two types of experiments, one at constant orientation and another with simultaneous translation and rotation, were conducted utilizing the manipulator. The experiments were repeated for five individual IMUs successively. Application of the calibration and optimization methods yielded an average decrease of 95% in the maximum position error compared to the results of common motion reconstruction. Moreover, the average position error over the measurement duration decreased by nearly 90%. The proposed method is applicable to velocity, position, and orientation constraints for every experiment that starts and ends at standstill.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.