Evidence map›Paper›PMID 36816293›Full record

ArticleHeliyon2023

ADDISC lumbar disc prosthesis: Analytical and FEA testing of novel implants.

Amparo Vanaclocha, Vicente Vanaclocha, Carlos M Atienza, Pablo Jorda-Gomez, Cristina Diaz-Jimenez, Jose A Garcia-Lorente, Nieves Saiz-Sapena, Leyre Vanaclocha

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.3field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Towards biomimetic evolution of artificial intervertebral disc: a review.Medical & biological engineering & computing · 2025
    Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 7 institutions in 1 country.

Amparo VanaclochaEscuela de Doctorado, Universitat Politècnica de Valencia, Camí de Vera, s/n, 46022, Valencia, Spain.
Vicente VanaclochaUniversity of Valencia, Avenida de Blasco Ibáñez, 15, 46010 Valencia, Spain.
Carlos M AtienzaInstituto de Biomecánica (IBV), Universitat Politècnica de Valencia, Camí de Vera, s/n, 46022 Valencia, Spain.
Pablo Jorda-GomezHospital General Universitario de Castellón, Avenida de Benicàssim, 128, 12004 Castelló de la Plana, Spain.
Cristina Diaz-JimenezIndustry Association of Navarra, Carretera de Pamplona, 1, 31191 Cordovilla, Navarra, Spain.
Jose A Garcia-LorentePublic University of Navarra, Av. Cataluña, s/n, 31006 Pamplona, Navarra, Spain.
Nieves Saiz-SapenaHospital General Universitario de Valencia, Avenida Tres Cruces 2, Valencia, Spain.
Leyre VanaclochaMedius Klinik, Ostfildern-Ruit Klinik für Urologie, Hedelfinger Strasse 166, 73760 Ostfildern, Esslingen, Baden-Wurtemberg, Germany.
Asociación de la Industria Navarra · ESBiomechanics Institute of Valencia · ESHospital General Universitari de Castelló · ESHospital General Universitario De Valencia · ESUniversidad de Navarra · ESUniversitat de València · ESUniversitat Politècnica de València · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The intact intervertebral disc is a six-freedom degree elastic deformation structure with shock absorption. "Ball-and-socket" TDR do not reproduce these properties inducing zygapophyseal joint overload. Elastomeric TDRs reproduce better normal disc kinematics, but repeated core deformation causes its degeneration. We aimed to create a new TDR (ADDISC) reproducing healthy disc features. We designed TDR, analyzed (Finite Element Analysis), and measured every 500,000 cycles for 10 million cycles of the flexion-extension, lateral bending, and axial rotation cyclic compression bench-testing. In the inlay case, we weighted it and measured its deformation. ADDISC has two semi-spherical articular surfaces, one rotation centre for flexion, another for extension, the third for lateral bending, and a polycarbonate urethane inlay providing shock absorption. The first contact is between PCU and metal surfaces. There is no metal-metal contact up to 2000 N, and CoCr28Mo6 absorbs the load. After 10 million cycles at 1.2-2.0 kN loads, wear 140.96 mg (35.50 mm

Indexed as

Degenerative disc diseaseIntervertebral disc degenerationLumbar artificial disc replacementLumbar disc prosthesisTotal disc arthroplastyTotal disc replacement

Identifiers

PMID36816293
PMCPMC9929472
OpenAlexW4319222107

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.