Evidence map›Paper›PMID 36814748›Full record

ArticleCureus2023

Processing Validation Metrics of Syva Enzyme-Multiplied Immunoassay Technique (EMIT) Methotrexate Assay for Beckman Coulter System.

Saurav Nayak, Suprava Patel, Rachita Nanda, Seema Shah, Eli Mohapatra

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Saurav NayakBiochemistry, All India Institute of Medical Sciences, Bhubaneswar, IND.
Suprava PatelBiochemistry, All India Institute of Medical Sciences, Raipur, IND.
Rachita NandaBiochemistry, All India Institute of Medical Sciences, Raipur, IND.
Seema ShahBiochemistry, All India Institute of Medical Sciences, Raipur, IND.
Eli MohapatraBiochemistry, All India Institute of Medical Sciences, Raipur, IND.
All India Institute of Medical Sciences Raipur · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHigh-dose methotrexate (HDMTX), defined as a dose greater than 500 mg/m METHODOLOGY: A total of 25 replicates (five replicates per run, for five runs) were analyzed for profiling. Precision, accuracy, linearity, limit of blank, limit of detection, and limit of quantification were determined using existing guidelines. Imprecision profile and limit of quantitation (LoQ) at 10% were determined by fitting data with hyperbolic regression.

resultsThe coefficient of variation percentage (CV%) for low, mid, and high-level internal quality control (IQC) was 1.25%, 3.45%, and 1.55%, respectively. Similarly, estimated bias was -4.58%, -3.54%, -7.21% for each level. The assay linearity was maintained from a range of 0.041-1.993 mmol/L with an R

conclusionSyva EMIT MTX assay can be precisely and accurately used to measure low levels of serum methotrexate at levels lower than claimed by the manufacturer, aiding in the monitoring of toxicity in patients.

Indexed as

accuracydrug monitoringimprecisionlinearityvalidation

Identifiers

PMID36814748
PMCPMC9939913
OpenAlexW4317632365

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.