A new paradigm of reliable sensing with field-deployed electrochemical sensors integrating data redundancy and source credibility.

Ajanta Saha, Sotoudeh Sedaghat, Sarath Gopalakrishnan, Jose Waimin, Aiganym Yermembetova, Nicholas Glassmaker, Charilaos Mousoulis, Ali Shakouri, Alexander Wei, Rahim Rahimi and 1 more

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ajanta SahaSchool of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47906, USA.
Sotoudeh SedaghatDepartment of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA.
Sarath GopalakrishnanSchool of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47906, USA.
Jose WaiminDepartment of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA.
Aiganym YermembetovaDepartment of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA.
Nicholas GlassmakerBirck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA.
Charilaos MousoulisSchool of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47906, USA.
Ali ShakouriSchool of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47906, USA.
Alexander WeiDepartment of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA.
Rahim RahimiDepartment of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA.
Muhammad A AlamSchool of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47906, USA. alam@purdue.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

For a continuous healthcare or environmental monitoring system, it is essential to reliably sense the analyte concentration reported by electrochemical sensors. However, environmental perturbation, sensor drift, and power-constraint make reliable sensing with wearable and implantable sensors difficult. While most studies focus on improving sensor stability and precision by increasing the system's complexity and cost, we aim to address this challenge using low-cost sensors. To obtain the desired accuracy from low-cost sensors, we borrow two fundamental concepts from communication theory and computer science. First, inspired by reliable data transmission over a noisy communication channel by incorporating redundancy, we propose to measure the same quantity (i.e., analyte concentration) with multiple sensors. Second, we estimate the true signal by aggregating the output of the sensors based on their credibility, a technique originally developed for "truth discovery" in social sensing applications. We use the Maximum Likelihood Estimation to estimate the true signal and the credibility index of the sensors over time. Using the estimated signal, we develop an on-the-fly drift-correction method to make unreliable sensors reliable by correcting any systematic drifts during operation. Our approach can determine solution pH within 0.09 pH for more than three months by detecting and correcting the gradual drift of pH sensors as a function of gamma-ray irradiation. In the field study, we validate our method by measuring nitrate levels in an agricultural field onsite over 22 days within 0.06 mM of a high-precision laboratory-based sensor. We theoretically demonstrate and numerically validate that our approach can estimate the true signal even when the majority (~ 80%) of the sensors are unreliable. Moreover, by restricting wireless transmission to high-credible sensors, we achieve near-perfect information transfer at a fraction of the energy cost. The high-precision sensing with low-cost sensors at reduced transmission cost will pave the way for pervasive in-field sensing with electrochemical sensors. The approach is general and can improve the accuracy of any field-deployed sensors undergoing drift and degradation during operation.