Evidence map›Paper›PMID 36811759›Full record

ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2023

Development of HPLC system that uses phase-separation multiphase flow as an eluent.

Noé Jallas, Daiki Ishikawa, Tetsuro Katayama, Aoi Kimura, Satoru Kinoshita, Kazuhiko Tsukagoshi

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 14 citations in OpenAlex.

  1. Direct visualization of phase-separation multiphase flow in a silica bead-packed microchannel using fluorescence microscopy.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025
    Article
  2. Article
  3. Article
  4. Phase-separation multiphase flow: preliminary application to analytical chemistry.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Noé JallasApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan.
Daiki IshikawaApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan.
Tetsuro KatayamaApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan.
Aoi KimuraApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan.
Satoru KinoshitaApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan.
Kazuhiko TsukagoshiApplied Chemistry, Graduate School of Science and Engineering, Doshisha University, Kyotanabe, 610-0321, Japan. ktsukago@mail.doshisha.ac.jp.
Doshisha University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We developed a new type of HPLC system that uses phase-separation multiphase flow as an eluent. A commercially available HPLC system with a packed separation column filled with octadecyl-modified silica (ODS) particles was used. First, as preliminary experiments, 25 kinds of mixed solutions of water/acetonitrile/ethyl acetate and water/acetonitrile were supplied to the system to act as eluents at 20 °C. 2,6-Naphthalenedisulfonic acid (NDS) and 1-naphthol (NA) mixture was used as a model and mixed analyte was injected into the system. Roughly speaking, they were not separated in organic solvent-rich eluents and well separated in water-rich eluents, in which NDS eluted faster than NA. This means that HPLC worked under a reverse-phase mode for separation at 20 °C. Next, the separation of the mixed analyte was examined on HPLC at 5 °C, and then after judging the results, four kinds of ternary mixed solutions were in detail as eluents on HPLC at 20 °C and 5 °C. Based on their volume ratio, the ternary mixed solutions acted as a two-phase separation mixed solution, leading to a phase-separation multiphase flow. Consequently, the solutions flowed homogeneously and heterogeneously in the column at 20 °C and 5 °C, respectively. For example, the ternary mixed solutions containing water/acetonitrile/ethyl acetate at volume ratios of 20:60:20 (organic solvent-rich) and 70:23:7 (water-rich) were delivered into the system as eluents at 20 °C and 5 °C. In the organic solvent-rich eluent, the mixture of NDS and NA was not separated at 20 °C but was separated at 5 °C, the elution of NA being faster than the one of NDS (phase-separation mode). In the water-rich eluent, the mixture of analytes was separated at both 20 °C and 5 °C, the elution of NDS being faster than the one of NA. The separation at 5 °C was more effective than at 20 °C (reverse-phase mode and phase-separation mode). This separation performance and elution order can be attributed to the phase-separation multiphase flow at 5 °C.

Indexed as

HPLCPhase-separation modePhase-separation multiphase flowTernary mixed solutionTwo-phase separation mixed solution

Identifiers

PMID36811759
OpenAlexW4321501405

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.