ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2023
Development of HPLC system that uses phase-separation multiphase flow as an eluent.
Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 14 citations in OpenAlex.
- Direct visualization of phase-separation multiphase flow in a silica bead-packed microchannel using fluorescence microscopy.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025Article
- Development of a HPLC system using a phase-separation multiphase flow as an eluent: an influence of column pressure on phase separation and chromatogram at room temperature.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2024Article
- Development of an HPLC device with water/acetonitrile with NaCl mixed solution that induces a phase-separation multiphase flow as the eluent in the separation column.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2024Article
- Phase-separation multiphase flow: preliminary application to analytical chemistry.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We developed a new type of HPLC system that uses phase-separation multiphase flow as an eluent. A commercially available HPLC system with a packed separation column filled with octadecyl-modified silica (ODS) particles was used. First, as preliminary experiments, 25 kinds of mixed solutions of water/acetonitrile/ethyl acetate and water/acetonitrile were supplied to the system to act as eluents at 20 °C. 2,6-Naphthalenedisulfonic acid (NDS) and 1-naphthol (NA) mixture was used as a model and mixed analyte was injected into the system. Roughly speaking, they were not separated in organic solvent-rich eluents and well separated in water-rich eluents, in which NDS eluted faster than NA. This means that HPLC worked under a reverse-phase mode for separation at 20 °C. Next, the separation of the mixed analyte was examined on HPLC at 5 °C, and then after judging the results, four kinds of ternary mixed solutions were in detail as eluents on HPLC at 20 °C and 5 °C. Based on their volume ratio, the ternary mixed solutions acted as a two-phase separation mixed solution, leading to a phase-separation multiphase flow. Consequently, the solutions flowed homogeneously and heterogeneously in the column at 20 °C and 5 °C, respectively. For example, the ternary mixed solutions containing water/acetonitrile/ethyl acetate at volume ratios of 20:60:20 (organic solvent-rich) and 70:23:7 (water-rich) were delivered into the system as eluents at 20 °C and 5 °C. In the organic solvent-rich eluent, the mixture of NDS and NA was not separated at 20 °C but was separated at 5 °C, the elution of NA being faster than the one of NDS (phase-separation mode). In the water-rich eluent, the mixture of analytes was separated at both 20 °C and 5 °C, the elution of NDS being faster than the one of NA. The separation at 5 °C was more effective than at 20 °C (reverse-phase mode and phase-separation mode). This separation performance and elution order can be attributed to the phase-separation multiphase flow at 5 °C.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.