Evidence map›Paper›PMID 36810986›Full record

SynthesisThe Cochrane database of systematic reviews2023

Catheter insertion techniques for improving catheter function and clinical outcomes in peritoneal dialysis patients.

Victoria R Briggs, Richard M Jacques, James Fotheringham, Ravi Maheswaran, Michael Campbell, Martin E Wilkie

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 13 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Non-infectious complications of peritoneal dialysis in children.Pediatric nephrology (Berlin, Germany) · 2025
    Review
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Victoria R BriggsDepartment of Nephrology, Calderdale and Huddersfield NHS Foundation Trust, Huddersfield, UK.
Richard M JacquesSchool of Health and Related Research, University of Sheffield, Sheffield, UK.
James FotheringhamSheffield Kidney Institute, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK.
Ravi MaheswaranSchool of Health and Related Research, University of Sheffield, Sheffield, UK.
Michael CampbellSchool of Health and Related Research, University of Sheffield, Sheffield, UK.
Martin E WilkieSheffield Kidney Institute, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK.
University of Sheffield · GBCalderdale and Huddersfield NHS Foundation Trust · GBSheffield Kidney Institute · GBSheffield Teaching Hospitals NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPeritoneal dialysis (PD) relies on the optimal functionality of the flexible plastic PD catheter present within the peritoneal cavity to enable effective treatment. As a result of limited evidence, it is uncertain if the PD catheter's insertion method influences the rate of catheter dysfunction and, thus, the quality of dialysis therapy. Numerous variations of four basic techniques have been adopted in an attempt to improve and maintain PD catheter function. This review evaluates the association between PD catheter insertion technique and associated differences in  PD catheter function and post-PD catheter insertion complications

objectivesOur aims were to 1) evaluate if a specific technique used for PD catheter insertion has lower rates of PD catheter dysfunction (early and late) and technique failure; and 2) examine if any of the available techniques results in a reduction in post-procedure complication rates including postoperative haemorrhage, exit-site infection and peritonitis. SEARCH

methodsWe searched the Cochrane Kidney and Transplant Register of Studies up to 24 November 2022 through contact with the Information Specialist using search terms relevant to this review. Studies in the Register are identified through searches of CENTRAL, MEDLINE, and EMBASE, conference proceedings, the International Clinical Trials Register (ICTRP) Search Portal and ClinicalTrials.gov. SELECTION CRITERIA: We included randomised controlled trials (RCTs) examining adults and children undergoing PD catheter insertion. The studies examined any two PD catheter insertion techniques, including laparoscopic, open-surgical, percutaneous and peritoneoscopic insertion. Primary outcomes of interest were PD catheter function and technique survival.  DATA COLLECTION AND ANALYSIS: Two authors independently performed data extraction and assessed the risk of bias for all included studies. Main outcomes in the Summary of Findings tables include primary outcomes - early PD catheter function, long-term PD catheter function, technique failure and postoperative complications. A random effects model was used to perform meta-analyses; risk ratios (RRs) were calculated for dichotomous outcomes, and mean differences (MD) were calculated for continuous outcomes, using 95% confidence intervals (CIs) for effect estimates. The certainty of the evidence was evaluated using the GRADE (Grades of Recommendation, Assessment, Development and Evaluation) approach.  MAIN

resultsSeventeen studies were included in this review. Nine studies were suitable for inclusion in quantitative meta-analysis (670 randomised participants). Five studies compared laparoscopic with open PD catheter insertion, and four studies compared a 'medical' insertion technique with open surgical PD catheter insertion: percutaneous (2) and peritoneoscopic (2). Random sequence generation was judged to be at low risk of bias in eight studies. Allocation concealment was reported poorly, with only five studies judged to be at low risk of selection bias. Performance bias was judged to be high risk in 10 studies. Attrition bias and reporting bias were judged to be low in 14 and 12 studies, respectively. Six studies compared laparoscopic PD catheter insertion with open surgical insertion. Five studies could be meta-analysed (394 participants). For our primary outcomes, data were either not reported in a format that could be meta-analysed (early PD catheter function, long-term catheter function) or not reported at all (technique failure). One death was reported in the laparoscopic group and none in the open surgical group. In low certainty evidence, laparoscopic PD catheter insertion may make little or no difference to the risk of peritonitis (4 studies, 288 participants: RR 0.97, 95% CI 0.63 to 1.48; I² = 7%), PD catheter removal (4 studies, 257 participants: RR 1.15, 95% CI 0.80 to 1.64; I² = 0%), and dialysate leakage (4 studies, 330 participants: RR 1.40, 95% CI 0.49 to 4.02; I² = 0%), but may reduce the risk of haemorrhage (2 studies, 167 participants: RR 1.68, 95% CI 0.28 to 10.31; I² = 33%) and catheter tip migration (4 studies, 333 participants: RR 0.43, 95% CI 0.20 to 0.92; I² = 12%). Four studies compared a medical insertion technique with open surgical insertion (276 participants). Technique failure was not reported, and no deaths were reported (2 studies, 64 participants). In low certainty evidence, medical insertion may make little or no difference to early PD catheter function (3 studies, 212 participants: RR 0.73, 95% CI 0.29 to 1.83; I² = 0%), while one study reported long-term PD function may improve with peritoneoscopic insertion (116 participants: RR 0.59, 95% CI 0.38 to 0.92). Peritoneoscopic catheter insertion may reduce the episodes of early peritonitis (2 studies, 177 participants: RR 0.21, 95% CI 0.06 to 0.71; I² = 0%) and dialysate leakage (2 studies, 177 participants: RR 0.13, 95% CI 0.02 to 0.71; I² = 0%). Medical insertion had uncertain effects on catheter tip migration (2 studies, 90 participants: RR 0.74, 95% CI 0.15 to 3.73; I² = 0%). Most of the studies examined were small and of poor quality, increasing the risk of imprecision. There was also a significant risk of bias therefore cautious interpretation of results is advised. AUTHORS'

conclusionsThe available studies show that the evidence needed to guide clinicians in developing their PD catheter insertion service is lacking. No PD catheter insertion technique had lower rates of PD catheter dysfunction. High-quality, evidence-based data are urgently required, utilising multi-centre RCTs or large cohort studies, in order to provide definitive guidance relating to PD catheter insertion modality.

Indexed as

Peritoneal DialysisPeritonitisAdultCathetersChildDialysis SolutionsHumansRenal DialysisDialysis Solutions

Identifiers

PMID36810986
PMCPMC9946371
OpenAlexW4321494839

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.