ArticleScientific reports2023
The magnetic field strength and the force distance dependency of the magnetically controlled growing rods used for early onset scoliosis.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- A Novel Concept and 3D Coupler for Robotic Correction of Spinal Deformities: In Vitro Experimental Testing.International journal of spine surgery · 2026Article
- Advances in the diagnosis and treatment of congenital scoliosis.European journal of medical research · 2025Review
- Beyond the gut: spectrum of magnetic surgery devices.Frontiers in surgery · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Magnetically controlled growing rods (MCGR's) have revolutionized the treatment of early-onset scoliosis (EOS) because painless lengthenings can be done in the outpatient clinic without anesthesia. Untreated EOS leads to respiratory insufficiency and reduced life expectancy. However, MCGR's have inherent complications like non-functioning of the lengthening mechanism. We quantify an important failure mechanism and give advice on how to avoid this complication. The magnetic field strength was measured on new/explanted rods at different distances between the external remote controller and the MCGR and likewise in patients before/after distractions. The magnetic field strength of the internal actuator decayed fast with increasing distances and plateaued at 25-30 mm approximating zero. Two new and 12 explanted MCGRs was used for the lab measurements of the elicited force using a forcemeter. At a distance of 25 mm, the force was reduced to approximately 40% (ca. 100 N) compared to zero distance (ca. 250 N), most so for explanted rods. This is used to point out the importance of minimizing the implantation depth to ensure proper functionality of the rod lengthening in clinical use for EOS patients. A distance of 25 mm from skin to MCGR should be considered a relative contraindication to clinical use in EOS patients.