ArticleEuropean radiology2023

X-ray dark-field chest radiography: a reader study to evaluate the diagnostic quality of attenuation chest X-rays from a dual-contrast scanning prototype.

Margarete Kattau, Konstantin Willer, Wolfgang Noichl, Theresa Urban, Manuela Frank, Fabio De Marco, Rafael Schick, Thomas Koehler, Hanns-Ingo Maack, Bernhard Renger and 7 more

Abstract read
In one paragraph

Article in European radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors.

Margarete KattauChair of Biomedical Physics, Munich Institute of Biomedical Engineering & School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany. m.kattau@outlook.de.ORCID http://orcid.org/0000-0002-1092-8262
Konstantin WillerChair of Biomedical Physics, Munich Institute of Biomedical Engineering & School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany.
Wolfgang NoichlChair of Biomedical Physics, Munich Institute of Biomedical Engineering & School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany.
Theresa UrbanChair of Biomedical Physics, Munich Institute of Biomedical Engineering & School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany.
Manuela FrankChair of Biomedical Physics, Munich Institute of Biomedical Engineering & School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany.
Fabio De MarcoChair of Biomedical Physics, Munich Institute of Biomedical Engineering & School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany.
Rafael SchickChair of Biomedical Physics, Munich Institute of Biomedical Engineering & School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany.
Thomas KoehlerPhilips Research, 22335, Hamburg, Germany.
Hanns-Ingo MaackPhilips Medical Systems DMC GmbH, 22335, Hamburg, Germany.
Bernhard RengerDepartment of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
Martin RenzDepartment of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
Andreas SauterDepartment of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
Yannik LeonhardtDepartment of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
Alexander FingerleDepartment of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
Marcus MakowskiDepartment of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
Daniela PfeifferDepartment of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
Franz PfeifferChair of Biomedical Physics, Munich Institute of Biomedical Engineering & School of Natural Sciences, Technical University of Munich, 85748, Garching, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare the visibility of anatomical structures and overall quality of the attenuation images obtained with a dark-field X-ray radiography prototype with those from a commercial radiography system.

methodsEach of the 65 patients recruited for this study obtained a thorax radiograph at the prototype and a reference radiograph at the commercial system. Five radiologists independently assessed the visibility of anatomical structures, the level of motion artifacts, and the overall image quality of all attenuation images on a five-point scale, with 5 points being the highest rating. The average scores were compared between the two image types. The differences were evaluated using an area under the curve (AUC) based z-test with a significance level of p ≤ 0.05. To assess the variability among the images, the distributions of the average scores per image were compared between the systems.

resultsThe overall image quality was rated high for both devices, 4.2 for the prototype and 4.6 for the commercial system. The rating scores varied only slightly between both image types, especially for structures relevant to lung assessment, where the images from the commercial system were graded slightly higher. The differences were statistically significant for all criteria except for the bronchial structures, the cardiophrenic recess, and the carina.

conclusionsThe attenuation images acquired with the prototype were assigned a high diagnostic quality despite a lower resolution and the presence of motion artifacts. Thus, the attenuation-based radiographs from the prototype can be used for diagnosis, eliminating the need for an additional conventional radiograph. KEY POINTS: • Despite a low tube voltage (70 kVp) and comparably long acquisition time, the attenuation images from the dark-field chest radiography system achieved diagnostic quality for lung assessment. • Commercial chest radiographs obtained a mean rating score regarding their diagnostic quality of 4.6 out of 5, and the grating-based images had a slightly lower mean rating score of 4.2 out of 5. • The difference in rating scores for anatomical structures relevant to lung assessment is below 5%.

Indexed as

Radiography, ThoracicThoraxHumansLungRadiographyX-RaysComparative studyDiagnostic X-ray radiologyThoracic radiography

Identifiers

PMID36806571
PMCPMC10326144

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.