Evidence map›Paper›PMID 36801860›Full record

ArticleNature communications2023

Sub-resolution contrast in neutral helium microscopy through facet scattering for quantitative imaging of nanoscale topographies on macroscopic surfaces.

Sabrina D Eder, Adam Fahy, Matthew G Barr, J R Manson, Bodil Holst, Paul C Dastoor

Open access · goldAbstract read
In one paragraph

Article in Nature communications, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 3 countries.

Sabrina D Eder *Department of Physics and Technology, University of Bergen, Bergen, Norway.ORCID http://orcid.org/0000-0002-3266-9089
Adam Fahy *Centre for Organic Electronics, University of Newcastle, Callaghan, NSW, 2308, Australia.ORCID http://orcid.org/0000-0001-7590-394X
Matthew G Barr *Centre for Organic Electronics, University of Newcastle, Callaghan, NSW, 2308, Australia.
J R MansonDepartment of Physics and Astronomy, Clemson University, Clemson, SC, 29634, USA.ORCID http://orcid.org/0000-0002-2196-447X
Bodil HolstDepartment of Physics and Technology, University of Bergen, Bergen, Norway.ORCID http://orcid.org/0000-0001-6809-2579
Paul C DastoorCentre for Organic Electronics, University of Newcastle, Callaghan, NSW, 2308, Australia. paul.dastoor@newcastle.edu.au.ORCID http://orcid.org/0000-0002-6573-7148
University of Newcastle Australia · AUUniversity of Bergen · NOClemson University · US

Funding

Norges Forskningsråd (Research Council of Norway) 250018/F20
6 · The paper itself

Abstract

Nanoscale thin film coatings and surface treatments are ubiquitous across industry, science, and engineering; imbuing specific functional or mechanical properties (such as corrosion resistance, lubricity, catalytic activity and electronic behaviour). Non-destructive nanoscale imaging of thin film coatings across large (ca. centimetre) lateral length scales, crucial to a wide range of modern industry, remains a significant technical challenge. By harnessing the unique nature of the helium atom-surface interaction, neutral helium microscopy images these surfaces without altering the sample under investigation. Since the helium atom scatters exclusively from the outermost electronic corrugation of the sample, the technique is completely surface sensitive. Furthermore, with a cross-section that is orders of magnitude larger than that of electrons, neutrons and photons, the probe particle routinely interacts with features down to the scale of surface defects and small adsorbates (including hydrogen). Here, we highlight the capacity of neutral helium microscopy for sub-resolution contrast using an advanced facet scattering model based on nanoscale features. By replicating the observed scattered helium intensities, we demonstrate that sub-resolution contrast arises from the unique surface scattering of the incident probe. Consequently, it is now possible to extract quantitative information from the helium atom image, including localised ångström-scale variations in topography.

Identifiers

PMID36801860
PMCPMC9938237
OpenAlexW4321243236

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.