Evidence map›Paper›PMID 36798927›Full record

ArticleTranslational pediatrics2023

Clinical performance evaluation of serum amyloid A module of Mindray BC-7500CS automated hematology analyzer.

Jincheng Dai, Xiaoyu Zhang, Jing Zhou, Wei Pan, Fei Yu

Open access · diamondAbstract read
In one paragraph

Article in Translational pediatrics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Jincheng Dai *Department of Clinical Laboratory, Children's Hospital of Nanjing Medical University, Nanjing, China.
Xiaoyu Zhang *Department of Clinical Laboratory, Children's Hospital of Nanjing Medical University, Nanjing, China.
Jing Zhou *Department of Clinical Laboratory, Children's Hospital of Nanjing Medical University, Nanjing, China.
Wei PanDepartment of Clinical Laboratory, Children's Hospital of Nanjing Medical University, Nanjing, China.
Fei YuDepartment of Clinical Laboratory, Children's Hospital of Nanjing Medical University, Nanjing, China.
Nanjing Children's Hospital · CNNanjing Medical University · CNSecond Affiliated Hospital of Nanjing Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Laboratory detection of high values of serum amyloid A (SAA) is impaired by the hook effect. In response to this problem, Mindray has launched the new generation BC-7500CS automated hematology analyzer with an SAA autodilution (SAA-D) function. The present study aimed to verify the performance of the SAA module. Methods: Venous whole-blood specimens anticoagulated with EDTA-K2 were randomly collected from outpatients and inpatient of the Children's Hospital of Nanjing Medical University (CH). Background, repeatability, precision, linear range, intermode comparison, and interference of the SAA module of the Mindray BC-7500CS were evaluated, and the performance of the SAA-D function was verified. Results: The Mindray BC-7500CS showed an SAA background of 0.14 mg/L, well below that claimed by the manufacturer. Repeatability of SAA with standard deviation (SD) <0.6 mg/L and coefficient of variation (CV) <6%, the quality control (QC) precision was less than 8%. The measured value of the linear range was essentially consistent with the theoretical value, and the maximum measured values could reach 1932.38 mg/L. The deviation between whole-blood mode and micro-whole-blood mode was small (r=0.999), and the SAA module displayed high anti-interference ability. In addition, the measured results of specimens with high SAA concentration diluted by SAA-D were close to those after manual dilution (r=0.993). Conclusions: The SAA module of the Mindray BC-7500CS had excellent performance, and the SAA-D function was highly accurate at measuring specimens with high SAA concentration, enabling reliable SAA detection in the laboratory and clinical practice.

Indexed as

BC-7500CShigh SAA concentrationperformance evaluationSAA autodilution (SAA-D)serum amyloid A (SAA)

Identifiers

PMID36798927
PMCPMC9926133
OpenAlexW4316113746

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.