Evidence map›Paper›PMID 36798885›Full record

ArticleDigital health

Improving the reliability of smartphone-based urine colorimetry using a colour card calibration method.

Muhaimin Noor Azhar, Aida Bustam, Fathmath Sausan Naseem, Soo Siew Shuin, Mohd Hafyzuddin Md Yusuf, Naseeha Ubaidi Hishamudin, Khadijah Poh

Abstract read
In one paragraph

Article in Digital health. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Muhaimin Noor AzharFaculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.ORCID https://orcid.org/0000-0002-1085-0725
Aida BustamFaculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.ORCID https://orcid.org/0000-0001-9403-0734
Fathmath Sausan NaseemFaculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
Soo Siew ShuinFaculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
Mohd Hafyzuddin Md YusufFaculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.ORCID https://orcid.org/0000-0003-2862-9954
Naseeha Ubaidi HishamudinDepartment of Emergency Medicine, University Malaya Medical Center (UMMC), Kuala Lumpur, Malaysia.
Khadijah PohFaculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.ORCID https://orcid.org/0000-0003-1374-5012

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Urine colorimetry using a digital image-based colorimetry is potentially an accessible hydration assessment method. This study evaluated the agreement between urine colorimetry values measured with different smartphone brands under various lighting conditions in patients with dengue fever. Methods: The urine samples were photographed in a customized photo box, under five simulated lighting conditions, using five smartphones. These images were analyzed using Adobe Photoshop to obtain urine Red, Green and Blue (RGB) values with and without colour correction. A commercially available colour calibration card was used for colour correction. Using intraclass correlation coefficient (ICC), inter-phone and intra-phone agreements of urine RGB values were analyzed. Results: Without colour correction, the various smartphones produced the highest agreement for Blue and Green values under the 'daylight' lighting condition. With colour correction, ICC values showed 'exceptional' inter-phone and intra-phone agreement for the Blue and Green values (ICC > 0.9). Red values showed 'poor' (ICC < 0.5) agreement with and without colour correction in all lighting conditions. Out of the five phones compared in this study, Phone 4 produced the lowest intra-phone agreement. Conclusions: Colour calibration using photo colour cards improved the reliability of smartphone-based urine colorimetry, making this a promising point-of-care hydration assessment tool using the ubiquitous smartphone.

Indexed as

colour calibrationdehydrationdenguemediaRGBsmartphoneUrine colorimetry

Identifiers

PMID36798885
PMCPMC9926368

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.