Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle.

Zhenwei Li, Qingqing Xu, Ning Huangfu, Zewei Sun, Jia Su

Open access · goldAbstract read
In one paragraph

Article in Clinical cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Zhenwei LiDepartment of Cardiology, Ningbo Hospital of Zhejiang University, Ningbo, China.ORCID http://orcid.org/0000-0003-4274-6620
Qingqing XuDepartment of Nephrology, Ningbo Hospital of Zhejiang University, Ningbo, China.
Ning HuangfuDepartment of Cardiology, Ningbo Hospital of Zhejiang University, Ningbo, China.
Zewei SunDepartment of Cardiology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Jia SuDepartment of Cardiology, Ningbo Hospital of Zhejiang University, Ningbo, China.
Ningbo University · CNFirst Affiliated Hospital Zhejiang University · CN

Funding

Key Technology R&D Program of Ningbo 2022Z149The Key Laboratory of Precision Medicine for Atherosclerotic Diseases of Zhejiang Province 2022E10026
6 · The paper itself

Abstract

backgroundLeft bundle branch pacemakers (LBBPs) can better maintain ventricular electrical synchronization than traditional right ventricular pacing (RVP). Temporary cardiac pacing (TCP) is needed to ensure the safety of the operation in patients undergoing LBBP. Currently, there are two methods of installing TCP in conventional permanent pacemaker implantation. HYPOTHESIS: To evaluate the safety and efficiency of replacing femoral vein pacing with atrial spiral pacing in the right ventricle for temporary cardiac pacing (TCP) during left bundle branch pacemaker (LBBP) implantation.

methodA total of 179 patients who underwent TCP during LBBP were selected for retrospective analysis from April 2019 to 2021 and divided into two groups: the atrial spiral electrode group (n = 76) and the femoral vein electrode group (n = 103). The following were observed: operation time; radiation dose; radiation time; operation expenses; hospitalization time; pacemaker parameters immediately after the operation and at 1 week, 1 month, 3 months, and 6 months after the operation; operation complications and femoral vein puncture point complications were observed in the two groups.

resultsCompared to the femoral vein electrode group, the atrial electrode group had significantly lower operation times ([116.86 ± 24.63] versus [128.94 ± 25.27] min, p < 0.05), radiation doses ([805.07 ± 132.94] versus [846.42 ± 87.37] mgy, p < 0.05), and decreased risk of a displaced or dislodged temporary pacing electrode during the operation ([0.00%] versus [4.85%], p < 0.05). The atrial electrode group did not have significant operation costs or material costs associated with femoral vein temporary pacing electrode implantation. In addition, the atrial electrode group did not have an increased risk of pacemaker-related infections, and the parameters of the pacemaker were unaffected. However, some puncture point complications appeared in the femoral vein electrode group (8 cases of local subcutaneous hematoma, 3 cases of pseudoaneurysms, 3 cases of arteriovenous fistula).

conclusionThe replacement of the femoral vein pacing electrode with an atrial spiral pacing electrode in the right ventricle for TCP during LBBP implantation was safe and effective.

Indexed as

Atrial FibrillationPacemaker, ArtificialCardiac Pacing, ArtificialElectrocardiographyFemoral VeinHeart VentriclesHumansRetrospective StudiesTreatment Outcomeatrial spiral pacemaker electrodefemoral vein pacemaker electrodeleft bundle branch pacemaker

Identifiers

PMID36798033
PMCPMC10106659
OpenAlexW4321165741

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.