ArticleOrthopaedic surgery2023
Biomechanical Properties of Bionic Collum Femoris Preserving Hip Prosthesis: A Finite Element Analysis.
Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 6 citations in OpenAlex.
- Diagnosis and treatment of Pipkin type IV femoral head fracture : a finite element analysis.BMC musculoskeletal disorders · 2026Article
- Global trends in proximal femoral trabecular research: A bibliometric and visualized analysis.Journal of orthopaedics · 2025Article
- Biomechanical comparison of a novel triangular fixation stem and a conventional fixation stem in a model of a prosthesis for ultrashort residual proximal femur reconstruction: a finite element analysis study.BMC musculoskeletal disorders · 2025Article
- Integrating finite element analysis in total hip arthroplasty for childhood hip disorders: Enhancing precision and outcomes.World journal of orthopedics · 2025Article
- Biomechanical impact of enoxaparin sodium-chitosan-PMMA bone cement in hip arthroplasty: a preliminary finite element analysis.Frontiers in surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 4 institutions in 2 countries.
Funding
Abstract
objectiveCompared with total hip replacement, conventional collum femoris preserving prosthesis has a better bone retention effect. However, damage to the trabecular bone of the proximal femur leads to inevitable abnormal stress distribution, which leads to increased risks of femoral neck bone absorption, periprosthetic fracture, prosthesis loosening, rotation, and sinking. Thus, we compare the biomechanical properties of collum femoris preserving (CFP) and bionic collum femoris preserving (BCFP) hip prostheses.
methodsThe Sawbone digital model (#3503, left, medium) was selected as the research object. We used the Mimics 21.0 software to reconstruct the digital model of the femur and the SolidWorks 2019 software to build and assemble the three-dimensional models of CFP and BCFP prostheses. With the ANSYS Workbench 2021R1 software, the models were meshed and assigned values to simulate the load of a single foot under slow walking. We measured the mechanical distribution of the whole model and obtained the stress nephogram.
resultsFor CFP prosthesis, the peak stresses of the medial interface of the stem neck, the lateral interface of the stem neck, and the end of the stem were 64.894, 32.199, and 8.578 MPa, respectively; the peak stresses of the medial surface of the femoral shaft, the lateral surface of femoral shaft, the medial femoral neck bone-prosthesis interface (osteotomy interface), the lateral femoral neck bone-prosthesis interface (basal area), the lateral femoral neck bone-prosthesis interface (osteotomy interface), and the greater trochanter area were 28.093, 24.790, 14.388, 5.118, 4.179, and 8.245 MPa, respectively; the valley stress of the greater trochanter area was 1.134 MPa. For BCFP prosthesis, the peak stresses of the medial interface of the stem neck, the lateral interface of the stem neck, and the end of the stem were 47.015, 26.771, and 47.593 MPa, respectively; the peak stress of tension screw was 15.739 MPa; the peak stresses of the medial surface of the femoral shaft, the lateral surface of femoral shaft, the medial femoral neck bone-prosthesis interface (osteotomy interface), the lateral femoral neck bone-prosthesis interface (basal area), the lateral femoral neck bone-prosthesis interface (osteotomy interface) and the greater trochanter area were 28.581, 25.364, 15.624, 6.434, 4.986, and 8.796 MPa, respectively; the valley stress of the greater trochanter area was 1.419 MPa; the peak stress of bone-metal interface between the tension screw and the lateral surface of the femur was 5.858 MPa.
conclusionCompared with the CFP prosthesis, the design of the BCFP prosthesis is based on the lever balance theory. With the bionic reconstruction of tension trabeculae, BCFP prosthesis makes up for the defects of CFP prosthesis design, optimizes the stress distribution, and reduces the stress shelter effect of the proximal femur, which has better biomechanical properties.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.