Evidence map›Paper›PMID 36797394›Full record

Trial reportScientific reports2023

Electric impedance tomography and protective mechanical ventilation in elective robotic-assisted laparoscopy surgery with steep Trendelenburg position: a randomized controlled study.

Pasquale Buonanno, Annachiara Marra, Carmine Iacovazzo, Raffaele Merola, Andrea Uriel De Siena, Giuseppe Servillo, Maria Vargas

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Pasquale BuonannoDepartment of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Via Pansini 5, 80100, Naples, Italy.
Annachiara MarraDepartment of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Via Pansini 5, 80100, Naples, Italy.
Carmine IacovazzoDepartment of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Via Pansini 5, 80100, Naples, Italy.
Raffaele MerolaDepartment of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Via Pansini 5, 80100, Naples, Italy.
Andrea Uriel De SienaDepartment of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Via Pansini 5, 80100, Naples, Italy.
Giuseppe ServilloDepartment of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Via Pansini 5, 80100, Naples, Italy.
Maria VargasDepartment of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Via Pansini 5, 80100, Naples, Italy. vargas.maria82@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrical impedance tomography (EIT) reconstructs functional lung images and evaluates the variations of impedance during the breathing cycle. The aim of this study was to evaluate the effect of protective mechanical ventilation on ventilation distributions recorded by the EIT during elective robotic-assisted laparoscopy surgery with steep Trendelenburg position. This prospective, randomized single center study included patients with healthy lungs undergoing elective robot-assisted laparoscopic urological surgery in general anesthesia. Patients were randomly assigned to either protective lung ventilation or conventional ventilation. In the protective ventilation group, tidal volume (TV) was set at 6 ml/Kg predicted body weight (PBW), with PEEP 6 cmH

Indexed as

LaparoscopyRobotic Surgical ProceduresElectric ImpedanceHead-Down TiltHumansPositive-Pressure RespirationProspective StudiesRespiration, ArtificialTidal VolumeTomography

Identifiers

PMID36797394
PMCPMC9935531

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.