Evidence map›Paper›PMID 36796804›Full record

ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2023

[Effectiveness of three-dimensional visible technique without fluoroscopy versus two-dimensional fluoroscopy in reduction of unstable pelvic fractures].

Jiaqi Li, Hua Chen, Wei Zhang, Hongzhe Qi, Zhengguo Zhu, Zuhao Chang, Lin Qi, Feng Zhou, Haoyang Liu, Peifu Tang

Abstract readComparative StudyEnglish Abstract
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. [A clinical study of HoloSight Orthopaedic Trauma Surgery Robot-assisted infra-acetabular screw placement for acetabular fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jiaqi LiChinese PLA General Medical School, Beijing, 100853, P. R. China.
Hua ChenDepartment of Orthopaedic Trauma, Chinese PLA General Hospital, Beijing, 100048, P. R. China.
Wei ZhangAI Sports Engineering Lab, School of Sports Engineering, Beijing Sport University, Beijing, 100084, P. R. China.
Hongzhe QiChinese PLA General Medical School, Beijing, 100853, P. R. China.
Zhengguo ZhuChinese PLA General Medical School, Beijing, 100853, P. R. China.
Zuhao ChangChinese PLA General Medical School, Beijing, 100853, P. R. China.
Lin QiChinese PLA General Medical School, Beijing, 100853, P. R. China.
Feng ZhouAI Sports Engineering Lab, School of Sports Engineering, Beijing Sport University, Beijing, 100084, P. R. China.
Haoyang LiuAI Sports Engineering Lab, School of Sports Engineering, Beijing Sport University, Beijing, 100084, P. R. China.
Peifu TangDepartment of Orthopaedic Trauma, Chinese PLA General Hospital, Beijing, 100048, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To compare the reduction qualities of three-dimensional visible technique without fluoroscopy and two-dimensional fluoroscopy for unstable pelvic fractures during operations. Methods: The clinical data of 40 patients with unstable pelvic fractures, who met the selection criteria in three clinical centers between June 2021 and September 2022, were retrospectively analyzed. According to the reduction methods, the patients were divided into two groups. Twenty patients in trial group were treated with unlocking closed reduction system combined with three-dimensional visible technique without fluoroscopy; 20 patients in control group with unlocking closed reduction system under two-dimensional fluoroscopy. There was no significant difference in the gender, age, injury mechanism, Tile type of fracture, Injury Severity Score (ISS), and the time between injury to operation between the two groups ( Results: All operations were successfully completed in both groups. According to the Matta criteria, the qualities of fracture reduction were rated as excellent in 19 patients (95%) in trial group, which was better than that in the control group (13 cases, 65%), with a significant difference ( Conclusion: Compared to using unlocking closed reduction system under two-dimensional fluoroscopy, three-dimensional visible technique without fluoroscopy can significantly improve the reduction quality of unstable pelvic fractures without prolonging the operative time, and is valuable to reduce iatrogenic radiation exposure for patients and medical workers.

Indexed as

Fractures, BonePelvic BonesBlood Loss, SurgicalFluoroscopyFracture Fixation, InternalHumansRetrospective StudiesTreatment Outcomeclosed reductionPelvic fracturethree-dimensional visible techniqueunstable fracture

Identifiers

PMID36796804
PMCPMC9970777

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.