Evidence map›Paper›PMID 36794847›Full record

ArticleInternational braz j urol : official journal of the Brazilian Society of Urology

Technical and anatomical challenges to approach robotic-assisted radical prostatectomy in patients with Urolift®.

Marcio Covas Moschovas, David Grant Loy, Abdel Jaber, Shady Saikali, Travis Rogers, Sarah Kind, Vipul Patel

Open access · diamondAbstract readVideo-Audio Media
In one paragraph

Article in International braz j urol : official journal of the Brazilian Society of Urology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. A Comprehensive Review of the Current State of Robot-assisted Laparoscopic Salvage Prostatectomy.International braz j urol : official journal of the Brazilian Society of Urology
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Marcio Covas MoschovasAdventHealth Global Robotics Institute, FL, USA.
David Grant LoyAdventHealth Global Robotics Institute, FL, USA.
Abdel JaberAdventHealth Global Robotics Institute, FL, USA.
Shady SaikaliAdventHealth Global Robotics Institute, FL, USA.
Travis RogersAdventHealth Global Robotics Institute, FL, USA.
Sarah KindAdventHealth Global Robotics Institute, FL, USA.
Vipul PatelAdventHealth Global Robotics Institute, FL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionUrolift® is a surgical modality to treat lower urinary tract symptoms (LUTS) in patients with enlarged prostates (1). However, the inflammatory process caused by the device usually displaces the prostate's anatomical landmarks and challenges surgeons performing robotic-assisted radical prostatectomy (RARP). In this video, we will illustrate several technical challenges in patients with Urolift ® who underwent RARP. MATERIAL AND

methodsWe performed a video compilation with several surgical steps illustrating key aspects and critical details of the anterior bladder neck access, lateral bladder dissection from the prostate, and posterior prostate dissection to avoid ureteral and neural bundles injuries.

resultsWe perform our RARP technique with our standard approach in all patients (2-6). The beginning of the case is performed like every patient with an enlarged prostate. We first identify the anterior bladder neck and then complete its dissection with Maryland and Scissors. However, extra care must be taken in the anterior and posterior bladder neck approach due to the clips found during the dissection. The challenge starts when opening the lateral sides of the bladder until the base of the prostate. It is crucial to perform the bladder neck dissection beginning at the internal plane of the bladder wall. Such dissection is the easiest way to recognize the anatomical landmarks and potential foreign materials, such as clips, placed during previous surgeries. We cautiously work around the clip to avoid using cautery on the top of the metal clips because energy is transmitted from one edge to the other of the Urolift ®. This can be dangerous if the edge of the clip is close to the ureteral orifices. The clips are usually removed to minimize cautery conduction energy. Finally, after isolating and removing the clips, the prostate dissection and subsequent surgical steps are continued with our conventional technique. Before proceeding, we ensure that all clips are removed from the bladder neck to avoid complications during the anastomosis.

conclusionsRobotic-assisted radical prostatectomy in patients with Urolift ® is challenging due to modified anatomical landmarks and intense inflammatory processes in the posterior bladder neck. When dissecting the clips placed next to the base of the prostate, it is crucial to avoid cautery because energy conduction to the other edge of the Urolift ® can cause thermal damage to the ureters and neural bundles.

Indexed as

LaparoscopyProstatic HyperplasiaProstatic NeoplasmsRobotic Surgical ProceduresHumansMaleProstateProstatectomyUrinary Bladder

Identifiers

PMID36794847
PMCPMC10335883
OpenAlexW4321004454

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.