Evidence map›Paper›PMID 36793219›Full record

ArticleOrthopaedic surgery2023

A Novel Locking Buttress Plate Designed for Simultaneous Medial and Posterolateral Tibial Plateau Fractures: Concept and Comparative Finite Element Analysis.

Bangji Yan, Xiaotao Huang, Yingxing Xu, Chengshi Zou

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. [Research progress of tibial plateau fracture associated with proximal fibular fracture].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Review
  2. Biomechanical performance of proximal tibia fracture plates: A review.Chinese journal of traumatology = Zhonghua chuang shang za zhi · 2026
    Review
  3. Article
  4. [Application of minimally invasive techniques in clinical treatment of tibial plateau fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Review
  5. Article
  6. [Research progress on biomechanics for internal fixation in tibial plateau fracture].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Bangji YanDepartment of Orthopaedics and Traumatology, Cixi Hospital of Traditional Chinese Medicine, Ningbo, China.
Xiaotao HuangDepartment of Orthopaedics and Traumatology, Cixi Hospital of Traditional Chinese Medicine, Ningbo, China.ORCID https://orcid.org/0000-0003-1604-5767
Yingxing XuDepartment of Trauma Center, First Affiliated Hospital of Kunming Medical University, Kunming, China.ORCID https://orcid.org/0000-0001-7096-3716
Chengshi ZouDepartment of Radiology, Cixi Hospital of Traditional Chinese Medicine, Ningbo, China.

Funding

Zhejiang Cixi Science and Technology Planning Project CN2019022
6 · The paper itself

Abstract

objectiveThe complex tibial plateau fractures involving both medial and posterolateral columns are of frequent occurrence in clinics, but the existing fixation system cannot deal with medial and posterolateral fragments simultaneously. Therefore, a novel locking buttress plate named as medial and posterior column plate (MPCP) was designed in this study to fix the simultaneous medial and posterolateral tibial plateau fractures. Meanwhile, the comparative finite element analysis (FEA) was conducted to investigate the discrepancy between MPCP and traditional multiple plates (MP + PLP) in their biomechanical characteristics.

methodsTwo 3D finite element models of simultaneous medial and posterolateral tibial plateau fracture fixed with MPCP and MP + PLP system, respectively, was constructed. To imitate the axial stress of knee joint in ordinary life, diverse axial forces with 100, 500, 1000, and 1500 N were applied in the two fixation models, and then the equivalent displacement and stress nephograms and values were obtained.

resultsThe similar trend of displacement and stress increasing with the loads was observed in the two fixation models. However, several heterogeneities of displacement and stress distribution were found in the two fixation models. The max displacement and von Mises stress values of plates, screws, and fragments in the MPCP fixation model were significantly smaller than that in the MP + PLP fixation model, except for the max-shear stress values.

conclusionAs a single locking buttress plate, the MPCP system showed the excellent benefit on improving the stability of the simultaneous medial and posterolateral tibial plateau fractures, compared with the traditional double plate fixation system. However, the excessive shear stress around screw holes should be paid attention to prevent trabecular microfracture and screw loosening.

Indexed as

Tibial FracturesTibial Plateau FracturesBiomechanical PhenomenaBone PlatesFinite Element AnalysisFracture Fixation, InternalHumansStress, MechanicalBiomechanicsFinite Element AnalysisFixationLocking Buttress PlateTibial Plateau Fracture

Identifiers

PMID36793219
PMCPMC10102290

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.