Evidence map›Paper›PMID 36793079›Full record

ArticleJournal of intensive care2023

The time cost of physiologically ineffective intravenous fluids in the emergency department: an observational pilot study employing wearable Doppler ultrasound.

Jon-Émile S Kenny, Stanley O Gibbs, Delaney Johnston, Zhen Yang, Lisa M Hofer, Mai Elfarnawany, Joseph K Eibl, Amanda Johnson, Anthony J Buecker, Vivian C Lau and 1 more

Abstract read
In one paragraph

Article in Journal of intensive care, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Jon-Émile S KennyHealth Sciences North Research Institute, 56 Walford Road, Sudbury, ON, P3E2H3, Canada. jon-emile@heart-lung.org.ORCID http://orcid.org/0000-0002-3654-1146
Stanley O GibbsFlosonics Medical 325 W. Front Street, Toronto, ON, M5V2Y1, Canada.
Delaney JohnstonFlosonics Medical 325 W. Front Street, Toronto, ON, M5V2Y1, Canada.
Zhen YangFlosonics Medical 325 W. Front Street, Toronto, ON, M5V2Y1, Canada.
Lisa M HoferFlosonics Medical 325 W. Front Street, Toronto, ON, M5V2Y1, Canada.
Mai ElfarnawanyFlosonics Medical 325 W. Front Street, Toronto, ON, M5V2Y1, Canada.
Joseph K EiblHealth Sciences North Research Institute, 56 Walford Road, Sudbury, ON, P3E2H3, Canada.
Amanda JohnsonOSF Saint Francis Medical Center, 530 NE Glen Oak Ave, Peoria, IL, 61637, USA.
Anthony J BueckerOSF Saint Francis Medical Center, 530 NE Glen Oak Ave, Peoria, IL, 61637, USA.
Vivian C LauOSF Saint Francis Medical Center, 530 NE Glen Oak Ave, Peoria, IL, 61637, USA.
Benjamin O KempOSF Saint Francis Medical Center, 530 NE Glen Oak Ave, Peoria, IL, 61637, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLittle data exist on the time spent by emergency department (ED) personnel providing intravenous (IV) fluid to 'responsive' versus 'unresponsive' patients.

methodsA prospective, convenience sample of adult ED patients was studied; patients were enrolled if preload expansion was indicated for any reason. Using a novel, wireless, wearable ultrasound, carotid artery Doppler was obtained before and throughout a preload challenge (PC) prior to each bag of ordered IV fluid. The treating clinician was blinded to the results of the ultrasound. IV fluid was deemed 'effective' or 'ineffective' based on the greatest change in carotid artery corrected flow time (ccFT

results53 patients were recruited and 2 excluded for Doppler artifact. There were 86 total PCs included in the investigation comprising 81.7 L of administered IV fluid. 19,667 carotid Doppler cardiac cycles were analyzed. Using ccFT

conclusionsWe report the largest-known carotid artery Doppler analysis (i.e., roughly 20,000 cardiac cycles) in ED patients requiring IV fluid expansion. A clinically significant amount of time was spent providing physiologically ineffective IV fluid. This may represent an avenue to improve ED care efficiency.

Indexed as

Carotid arteryDoppler ultrasoundFluid refractoryFluid responsivenessPersonalized medicineQuality improvementWearable technology

Identifiers

PMID36793079
PMCPMC9933329

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.