Evidence map›Paper›PMID 36790819›Full record

ArticleTranslational vision science & technology2023

Ultrasonic Vitrectomy Performance Assessment Using Micro-Extensional Rheology.

John C P Hollister, Mercedes Rodriguez, Helia Hosseini, Asael Papour, Jean-Pierre Hubschman, H Pirouz Kavehpour

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

John C P HollisterDepartment of Mechanical and Aerospace Engineering, University of California - Los Angeles, Los Angeles, CA, USA.
Mercedes RodriguezStein Eye Institute, University of California - Los Angeles, Los Angeles, CA, USA.
Helia HosseiniDepartment of Bioengineering, University of California - Los Angeles, Los Angeles, CA, USA.
Asael PapourBausch and Lomb, St Louis, MO, USA.
Jean-Pierre HubschmanStein Eye Institute, University of California - Los Angeles, Los Angeles, CA, USA.
H Pirouz KavehpourDepartment of Mechanical and Aerospace Engineering, Department of Bioengineering, University of California - Los Angeles, Los Angeles, CA, USA.
University of California, Los Angeles · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purpose of this study was to assess the performance of ultrasonic (US) vitrectomy devices by quantifying and comparing its impact on extracted vitreous properties to conventional pneumatic blade (PB) cutters using micro-extensional rheology. US vitrectomy is a new technology that offers an alternative to PB cutters used in vitreo-retinal surgeries. Methods: Thirty-six porcine vitreous samples were extracted using US and PB cutters. Each sample was kept at 4°C and tested within 24 hours postmortem and 4 hours post-vitrectomy. A recently developed micro-extensional rheology technique is used to infer the relative protein fragment size of extracted vitreous by quantifying the extensional relaxation time. Results: US-extracted vitreous exhibited extensional relaxation times orders of magnitude lower than PB-extracted vitreous (0.37 ms and 27.25 ms, respectively). Relaxation time is directly correlated to the fragment size of the collagen fibers in the vitreous. The formation of beads-on-a-string droplets within the PB samples indicates the presence of larger collagen fragments. These droplets were not seen on US samples. Conclusions: This new micro-extensional rheology technique can identify significant differences in physical properties of extracted vitreous. Long relaxation times and beads-on-a-string droplets within the PB vitreous samples indicate larger protein fragments compared to the US samples. Translational Relevance: Higher fragmentation of vitreous and lower extensional relaxation times may improve retina safety due to a reduction in vitreo-retinal traction resulting from the continuous shear action and aspiration applied by ultrasonic vitrectomy technology.

Indexed as

VitrectomyVitreous BodyAnimalsCollagenRheologySwineUltrasonicsCollagen

Identifiers

PMID36790819
PMCPMC9940767
OpenAlexW4320857634

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.