ArticleAnnals of global health2023
Point-of-Care Testing in Chronic Kidney Disease of Non-Traditional Origin: Considerations for Clinical, Epidemiological, and Health Surveillance Research and Practice.
Article in Annals of global health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Recommendations of the Brazilian Society of Nephrology for the management of chronic kidney disease in primary health care.Jornal brasileiro de nefrologiaGuideline
- Point-of-Care Assessment of Kidney Function in Chronic Kidney Disease: Current Technologies and Future Perspectives.Medical sciences (Basel, Switzerland) · 2026Review
- Agreement between serum creatinine and fingerstick creatinine measurements in adult patients admitted to the emergency department.BMC emergency medicine · 2025Observational
- Choosing wisely: Improving decision-making for deployment of diagnostics in primary care settings.Journal of family medicine and primary care · 2025Article
- Validation of Nova Stat Profile Prime Plus point-of-care testing for dialysis in South Africa.African journal of laboratory medicine · 2025Article
- Point-of-care creatinine-based eGFR (StatSensor) in detecting kidney dysfunction (KD) among people living with HIV in Tanzania.PloS one · 2025Article
- Article
- Application and comparison of point-of-care devices for field evaluation of underlying health status of Guatemalan sugarcane workers.PLOS global public health · 2024Article
- EPI-CKD Brazil: point-of-care screening for chronic kidney disease during World Kidney Day.Jornal brasileiro de nefrologiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
Purpose: As the prevalence of chronic kidney disease of non-traditional origin (CKDnt) rises in low-resource settings, there is a need for reliable point-of-care creatinine testing. The purpose of this analysis was to assess the accuracy of two commonly used point-of-care creatinine devices, the i-STAT handheld (Abbott, Princeton, NJ, USA) and the StatSensor Creatinine (Nova Biomedical, Waltham, MA, USA) in comparison to venipuncture serum creatinine measures. The affordability, sensitivity, specificity, ease of use, and other considerations for each device are also presented. Methods: Three paired data sets were compared. We collected 213 paired i-STAT and venipuncture samples from a community study in Nicaragua in 2015-2016. We also collected 267 paired StatSensor Creatinine and venipuncture samples, including 158 from a community setting in Nicaragua in 2014-2015 and 109 from a Guatemala sugarcane worker cohort in 2017-2018. Pearson correlation coefficients, Bland-Altman plots, and no intercept linear regression models were used to assess agreement between point-of-care devices and blood samples. Results: The i-STAT performed the most accurately, overestimating creatinine by 0.07 mg/dL (95% CI: 0.02, 0.12) with no evidence of proportional bias. The StatSensor Creatinine performed well at low levels of creatinine (Mean (SD): 0.87 (0.19)). Due to proportional bias, the StatSensor Creatinine performed worse in the Nicaragua community setting where creatinine values ranged from 0.31 to 7.04 mg/dL. Discussion: Both devices provide acceptable sensitivity and specificity. Although adequate for routine surveillance, StatSensor Creatinine is less accurate as the values of measured creatinine increase, a consideration when using the point-of-care device for screening individuals at risk for CKDnt. Research, clinical, and screening objectives, cost, ease of use, and background prevalence of disease must all be carefully considered when selecting a point-of-care creatinine device. Conclusion: POC testing can be more accessible in resource-limited settings. The selection of the appropriate device will depend on the use-case.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.