Evidence map›Paper›PMID 36788198›Full record

Trial reportCanadian journal of anaesthesia = Journal canadien d'anesthesie2023

Applied forces with direct versus indirect laryngoscopy in neonatal intubation: a randomized crossover mannequin study.

Francesco Cavallin, Chiara Sala, Sabina Maglio, Benedetta Bua, Paolo Ernesto Villani, Arianna Menciassi, Selene Tognarelli, Daniele Trevisanuto

4 registry-linked trialsOpen access · bronzeAbstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Canadian journal of anaesthesia = Journal canadien d'anesthesie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 4 registered trials, which are not on this map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05197868 nacompletednot on this map

Applied Forces During Neonatal Intubation: a Randomized Crossover Mannequin Study

TypeinterventionalSponsorUniversity Hospital PadovaRan2022 to 2022Enrolled30ConditionsIntubation, Training, Neonate, ManikinArmsIntubation with traditional laryngoscope, Intubation with a straight blade video laryngoscope, Intubation with a hyper-angulated video laryngoscope
NCT06161389 nacompletednot on this map

Applied Forces During Neonatal Face Mask Ventilation With Different Face-mask Air Cushion

TypeinterventionalSponsorUniversity Hospital PadovaRan2023 to 2023Enrolled28ConditionsPositive Pressure Ventilation, Preterm Infants, ApneaArmsPartially inflated mask, Fully inflated mask
NCT06254651 nacompletednot on this mapstarted 2024, after this paper: background citation

Resuscitation Table Height for Face-mask Ventilation in Infants

TypeinterventionalSponsorUniversity Hospital PadovaRan2024 to 2024Enrolled28ConditionsAsphyxia, Resuscitation, Newborn MorbidityArmsHigh resuscitation table, Low resuscitation table
NCT07161752 nacompletednot on this mapstarted 2025, after this paper: background citation

Applied Forces During Neonatal Ventilation With Different Face Masks: a Randomized Crossover Manikin Study.

TypeinterventionalSponsorUniversity Hospital PadovaRan2025 to 2025Enrolled30ConditionsFace Mask Ventilation in Neonatal ResuscitationArmsAnatomical face mask 1, Anatomical face mask 2, Round face mask
3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Neonatal intubation: what are we doing?European journal of pediatrics · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Francesco CavallinIndependent statistician, Solagna, Italy.
Chiara SalaDepartment of Women and Children Health, University Hospital of Padua, Via Giustiniani, 3, 35128, Padua, Italy.
Sabina MaglioThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.
Benedetta BuaDepartment of Women and Children Health, University Hospital of Padua, Via Giustiniani, 3, 35128, Padua, Italy.
Paolo Ernesto VillaniDepartment of Woman's and Child's Health, Poliambulanza Hospital, Fondazione Poliambulanza, Brescia, Italy.
Arianna MenciassiThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.
Selene TognarelliThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.
Daniele TrevisanutoDepartment of Women and Children Health, University Hospital of Padua, Via Giustiniani, 3, 35128, Padua, Italy. daniele.trevisanuto@unipd.it.ORCID http://orcid.org/0000-0002-6462-0079
Scuola Superiore Sant'Anna · ITUniversity of Padua · ITFondazione Poliambulanza Istituto Ospedaliero · ITIstituto Nazionale di Statistica · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn adult mannequins, videolaryngoscopy improves glottic visualization with lower force applied to upper airway tissues and reduced task workload compared with direct laryngoscopy. This trial compared oropharyngeal applied forces and subjective workload during direct vs indirect (video) laryngoscopy in a neonatal mannequin.

methodsWe conducted a randomized crossover trial of intubation with direct laryngoscopy, straight blade videolaryngoscopy, and hyperangulated videolaryngoscopy in a neonatal mannequin. Thirty neonatal/pediatric/anesthesiology consultants and residents participated. The primary outcome measure was the maximum peak force applied during intubation. Secondary outcome measures included the average peak force applied during intubation, time needed to intubate, and subjective workload.

resultsDirect laryngoscopy median forces on the epiglottis were 8.2 N maximum peak and 6.8 N average peak. Straight blade videolaryngoscopy median forces were 4.7 N maximum peak and 3.6 N average peak. Hyperangulated videolaryngoscopy median forces were 2.8 N maximum peak and 2.1 N average peak. The differences were significant between direct laryngoscopy and straight blade videolaryngoscopy, and between direct laryngoscopy and hyperangulated videolaryngoscopy. Significant differences were also found in the top 10th percentile forces on the epiglottis and palate, but not in the median forces on the palate. Time to intubation and subjective workload were comparable with videolaryngoscopy vs direct laryngoscopy.

conclusionsThe lower force applied during videolaryngoscopy in a neonatal mannequin model suggests a possible benefit in reducing potential patient harm during intubation, but the clinical implications require assessment in future studies. REGISTRATION: ClinicalTrials.gov (NCT05197868); registered 20 January 2022.

Indexed as

LaryngoscopesLaryngoscopyCross-Over StudiesHumansInfant, NewbornIntubation, IntratrachealManikinsVideo Recordinginfant newbornintubationlaryngoscopymannequinvideolaryngoscopy

Identifiers

PMID36788198
OpenAlexW4320856369

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.