Evidence map›Paper›PMID 36787828›Full record

ArticleNeuroImage2023

Mapping of glutamate metabolism using 1H FID-MRSI after oral administration of [1-13C]Glc at 9.4 T.

Theresia Ziegs, Loreen Ruhm, Andrew Wright, Anke Henning

Open access · goldAbstract read
In one paragraph

Article in NeuroImage, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct (medRxiv : the preprint server for health sciences · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Theresia ZiegsHigh-Field MR Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany; IMPRS for Cognitive and Systems Neuroscience, Otfried-Müller-Str. 27, 72076 Tübingen, Germany. Electronic address: theresia.ziegs@tuebingen.mpg.de.
Loreen RuhmHigh-Field MR Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany; IMPRS for Cognitive and Systems Neuroscience, Otfried-Müller-Str. 27, 72076 Tübingen, Germany.
Andrew WrightHigh-Field MR Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany; IMPRS for Cognitive and Systems Neuroscience, Otfried-Müller-Str. 27, 72076 Tübingen, Germany.
Anke HenningHigh-Field MR Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany; Advanced Imaging Research Center, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX 75390, United States.
Max Planck Institute for Biological Cybernetics · DESouthwestern Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Glutamate is the major excitatory transmitter in the brain and malfunction of the related metabolism is associated with various neurological diseases and disorders. The observation of labeling changes in the spectra after the administration of a 13C labelled tracer is a common tool to gain better insights into the function of the metabolic system. But so far, only a very few studies presenting the labeling effects in more than two voxels to show the spatial dependence of metabolism. In the present work, the labeling effects were measured in a transversal plane in the human brain using ultra-short TE and TR 1H FID-MRSI. The measurement set-up was most simple: The [1-13C]Glc was administered orally instead of intravenous and the spectra were measured with a pure 1H technique without the need of a 13C channel (as Boumezbeur et al. demonstrated in 2004). Thus, metabolic maps and enrichment curves could be obtained for more metabolites and in more voxels than ever before in human brain. Labeling changes could be observed in [4-13C]glutamate, [3-13C]glutamate+glutamine, [2-13C]glutamate+glutamine, [4-13C]glutamine, and [3-13C]aspartate with a high temporal (3.6 min) and spatial resolution (32 × 32 grid with nominal voxel size of 0.33 µL) in five volunteers.

Indexed as

Glutamic AcidGlutamineAdministration, OralBrainCarbon IsotopesGlucoseHumansMagnetic Resonance SpectroscopyCarbon-13Carbon IsotopesGlucoseGlutamic AcidGlutamine[1-13C]Glc labelingGlutamatergic metabolismHuman brainProton magnetic resonance spectroscopy imagingUltra-high field strengths

Identifiers

PMID36787828
PMCPMC10030312
OpenAlexW4320181408

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.