Evidence map›Paper›PMID 36786967›Full record

ArticleOphthalmology and therapy2023

Anterior Segment Characteristics of Eyes with Anterior Chamber Depth Less than 2.8 mm and Axial Length Greater than 25 mm.

Lingling Niu, Xiumei Luo, Xueli Chen, Xiaoying Wang, Xingtao Zhou, Yishan Qian

Abstract read
In one paragraph

Article in Ophthalmology and therapy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Correlation of iris-ciliary angle with haptic position and vault after implantation of implantable collamer lens.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Observational
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Lingling Niu *Department of Ophthalmology, Eye and ENT Hospital, NHC Key Laboratory of Myopia, Fudan University, Shanghai, People's Republic of China.
Xiumei Luo *Department of Ophthalmology, Eye and ENT Hospital, NHC Key Laboratory of Myopia, Fudan University, Shanghai, People's Republic of China.
Xueli ChenDepartment of Ophthalmology, Eye and ENT Hospital, NHC Key Laboratory of Myopia, Fudan University, Shanghai, People's Republic of China.
Xiaoying WangDepartment of Ophthalmology, Eye and ENT Hospital, NHC Key Laboratory of Myopia, Fudan University, Shanghai, People's Republic of China.
Xingtao ZhouDepartment of Ophthalmology, Eye and ENT Hospital, NHC Key Laboratory of Myopia, Fudan University, Shanghai, People's Republic of China. doctzhouxingtao@163.com.
Yishan QianDepartment of Ophthalmology, Eye and ENT Hospital, NHC Key Laboratory of Myopia, Fudan University, Shanghai, People's Republic of China. thronebird31@hotmail.com.ORCID http://orcid.org/0000-0001-8698-3316

Funding

National Natural Science Foundation of China 81770955
6 · The paper itself

Abstract

introductionThis study aimed to investigate anterior segment parameters of eyes, with anterior chamber depth (ACD) less than 2.8 mm and axial length greater than 25.0 mm.

methodsThis cross-sectional study included 180 myopic eyes of 180 consecutive patients with axial length greater than 25.0 mm. Patients were divided into low ACD (ACD < 2.8 mm, n = 56) and normal ACD (ACD ≥ 2.8 mm, n = 124) groups. Anterior segment parameters were measured using Scheimpflug imaging and ultrasound biomicroscopy. A general linear model was used to compare parameters between the two groups, after adjusting for age and spherical equivalent.

resultsCompared with the normal ACD group, the low ACD group had lower values for the following parameters: corneal diameter, trabecular-anterior iris surface angle, angle-opening distance at 500 μm, anterior chamber volume, anterior chamber width, anterior vault, iris thickness at 500 μm, ciliary sulcus-to-sulcus diameter, distance between cornea and sulcus, trabecular-ciliary process distance, maximum ciliary body thickness, ciliary process length, relative anterior vault, relative distance between cornea and sulcus, and relative lens position (general linear model, p < 0.05). In contrast, central corneal thickness, iris curvature, lens thickness, lens vault, and iris-ciliary angle were greater in the low ACD group (general linear model, p < 0.05).

conclusionA smaller anterior segment, as well as a thicker and more anteriorly positioned lens, may correlate with shallow ACD in eyes with long axial length.

Indexed as

Anterior chamber depthAxial lengthImplantable collamer lensMyopiaPrimary angle closure

Identifiers

PMID36786967
PMCPMC10011296

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.