Evidence map›Paper›PMID 36785775›Full record

ArticleACS measurement science au2022

AI-Assisted Fusion of Scanning Electrochemical Microscopy Images Using Novel Soft Probe.

Yi-Hong Lin, Chih-Ning Tsai, Po-Feng Chen, Yen-Tzu Lin, Sorour Darvishi, Hubert H Girault, Tung-Yi Lin, Mei-Yi Liao, Tzu-En Lin

Open access · goldAbstract read
In one paragraph

Article in ACS measurement science au, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 16 citations in OpenAlex.

  1. CytochromeProceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Yi-Hong LinInstitute of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan.
Chih-Ning TsaiInstitute of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan.
Po-Feng ChenInstitute of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan.
Yen-Tzu LinInstitute of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan.
Sorour DarvishiDepartment of Chemistry and Chemical Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Valais Wallis, CH-1950 Sion, Switzerland.
Hubert H GiraultDepartment of Chemistry and Chemical Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Valais Wallis, CH-1950 Sion, Switzerland.ORCID https://orcid.org/0000-0001-5573-5774
Tung-Yi LinInstitute of Traditional Medicine, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
Mei-Yi LiaoDepartment of Applied Chemistry, National Pingtung University, Pingtung 90003, Taiwan.ORCID https://orcid.org/0000-0003-3872-0049
Tzu-En LinInstitute of Biomedical Engineering, Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, 30010 Hsinchu, Taiwan.ORCID https://orcid.org/0000-0003-4291-3601
National Yang Ming Chiao Tung University · TWÉcole Polytechnique Fédérale de Lausanne · CHNational Pingtung University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Scanning electrochemical microscopy (SECM) is one of the scanning probe techniques that has attracted considerable attention because of its ability to interrogate surface morphology or electrochemical reactivity. However, the quality of SECM images generally depends on the sizes of the electrodes and many uncontrollable factors. Furthermore, manipulating fragile glass ultramicroelectrodes and blurred images sometimes frustrate researchers. To overcome the challenges of modern SECM, we developed novel soft gold probes and then established the AI-assisted methodology for image fusion. A novel gold microelectrode probe with high softness was developed to scan fragile samples. The distribution of EGFR (protein biomarker) in oral cancer was investigated. Then, we fused the optical microscopic and SECM images to enhance the image quality using Matlab software. However, thousands of fused images were generated by changing the parameters for image fusion, which is annoying for researchers. Thus, a deep learning model was built to select the best-fused images according to the contrast and clarity of the fused images. Therefore, the quality of the SECM images was improved using a novel soft probe and combining the image fusion technique. In the future, a new scanning probe with AI-assisted fused SECM image processing may be interpreted more preciously and contribute to the early detection of cancers.

Identifiers

PMID36785775
PMCPMC9885998
OpenAlexW4292370998

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.