Evidence map›Paper›PMID 36785571›Full record

ArticleACS measurement science au2022

Ultralow Limit Detection of Soluble HER2 Biomarker in Serum with a Fiber-Optic Ball-Tip Resonator Assisted by a Tilted FBG.

Marzhan Sypabekova, Aida Amantayeva, Luca Vangelista, Álvaro González-Vila, Christophe Caucheteur, Daniele Tosi

Open access · goldAbstract read
In one paragraph

Article in ACS measurement science au, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
3.7field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 42 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Article
  16. Label-free optical biosensors in the pandemic era.Nanophotonics (Berlin, Germany) · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 3 countries.

Marzhan SypabekovaNazarbayev University School of Medicine, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan.
Aida AmantayevaNazarbayev University School of Engineering and Digital Sciences, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan.
Luca VangelistaNazarbayev University School of Medicine, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan.
Álvaro González-VilaElectromagnetism and Telecommunication Department, University of Mons, Boulevard Dolez 31, 7000 Mons, Belgium.ORCID https://orcid.org/0000-0003-0294-1616
Christophe CaucheteurElectromagnetism and Telecommunication Department, University of Mons, Boulevard Dolez 31, 7000 Mons, Belgium.ORCID https://orcid.org/0000-0002-6453-6790
Daniele TosiNazarbayev University School of Engineering and Digital Sciences, 53 Kabanbay Batyr Avenue, 010000 Nur-Sultan, Kazakhstan.ORCID https://orcid.org/0000-0002-6500-4964
Nazarbayev University · KZUniversity of Mons · BEBaylor University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An optical-fiber biosensor has been developed for the detection of the breast cancer biomarker soluble human epidermal growth factor receptor-2 (sHER2). The sensor was fabricated by combining a tilted fiber Bragg grating (TFBG) with a ball resonator, allowing us to achieve an excellent sensitivity compared to other optical-fiber-based sensors. The sensor exhibits a resonance comb excited by the TFBG and the spectral profile of the ball resonator. The detection of sHER2 at extremely low concentrations was carried out by tracking the amplitude change of selected resonances. The therapeutic anti-HER2 monoclonal antibody Trastuzumab has been used to functionalize the biosensor with silane surface chemistry. The sensor features a sensitivity of 4034 dB/RIU with a limit of detection (LoD) in buffer and in a 1/10 diluted serum of 151.5 ag/mL and 3.7 pg/mL, respectively. At relatively high protein concentrations (64 ng/mL) binding to sHER (7.36 dB) as compared to control proteins (below 0.7 dB) attested the high specificity of sHER2 detection.

Identifiers

PMID36785571
PMCPMC9885947
OpenAlexW4283389752

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.