Evidence map›Paper›PMID 36785552›Full record

ReviewACS measurement science au2021

From Light Pipes to Substrate-Integrated Hollow Waveguides for Gas Sensing: A Review.

Diandra Nunes Barreto, Vjekoslav Kokoric, João Flávio da Silveira Petruci, Boris Mizaikoff

Open access · goldAbstract readReview
In one paragraph

Review in ACS measurement science au, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Diandra Nunes BarretoInstitute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-902, MG, Brazil.
Vjekoslav KokoricInstitute for Microanalysis Systems, Hahn-Schickard, Ulm 89077, Germany.
João Flávio da Silveira PetruciInstitute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-902, MG, Brazil.ORCID https://orcid.org/0000-0003-1121-2503
Boris MizaikoffInstitute for Microanalysis Systems, Hahn-Schickard, Ulm 89077, Germany.ORCID https://orcid.org/0000-0002-5583-7962
Universidade Federal de Uberlândia · BRUniversität Ulm · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Absorption-based spectroscopy in the mid-infrared (MIR) spectral range (i.e., 2.5-25 μm) is an excellent choice for directly sensing trace gas analytes providing discriminatory molecular information due to inherently specific fundamental vibrational, rovibrational, and rotational transitions. Complimentarily, the miniaturization of optical components has aided the utility of optical sensing techniques in a wide variety of application scenarios that demand compact, portable, easy-to-use, and robust analytical platforms yet providing suitable accuracy, sensitivity, and selectivity. While MIR sensing technologies have clearly benefitted from the development of advanced on-chip light sources such as quantum cascade and interband cascade lasers and equally small MIR detectors, less attention has been paid to the development of modular/tailored waveguide technologies reproducibly and reliably interfacing photons with sample molecules in a compact format. In this context, the first generation of a new type of hollow waveguides gas cells-the so-called substrate-integrated hollow waveguides (iHWG)-with unprecedented compact dimensions published by the research team of Mizaikoff and collaborators has led to a paradigm change in optical transducer technology for gas sensors. Features of iHWGs included an adaptable (i.e., designable) well-defined optical path length via the integration of meandered hollow waveguide structures at virtually any desired dimension and geometry into an otherwise planar substrate, a high degree of robustness, compactness, and cost-effectiveness in fabrication. Moreover, only a few hundred microliters of gas samples are required for analysis, resulting in short sample transient times facilitating a real-time monitoring of gaseous species in virtually any concentration range. In this review, we give an overview of recent advancements and achievements since their introduction eight years ago, focusing on the development of iHWG-based mid-infrared sensor technologies. Highlighted applications ranging from clinical diagnostics to environmental and industrial monitoring scenarios will be contrasted by future trends, challenges, and opportunities for the development of next-generation portable optical gas-sensing platforms that take advantage of a modular and tailorable device design.

Identifiers

PMID36785552
PMCPMC9836072
OpenAlexW3206450321

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390