ArticleFrontiers in bioengineering and biotechnology2023
A novel hybrid design and modelling of a customised graded Ti-6Al-4V porous hip implant to reduce stress-shielding: An experimental and numerical analysis.
Article in Frontiers in bioengineering and biotechnology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed.
- Comparison of Periprosthetic Femoral Bone Remodeling After Total Hip Arthroplasty with Zimmer VerSys Taper Stem or VerSys Midcoat Stem: Long-Term Outcomes.Journal of clinical medicine · 2026Article
- Direct ink writing of tantalum: tailorable hierarchical porous scaffold for osteogenesis.National science review · 2026Article
- Biomechanical evaluation of 3D-printed porous lattice versus solid mandibular implants: an in vitro study.Scientific reports · 2026Article
- A review of 3D printed medical implant design.3D printing in medicine · 2026Article
- Design and performance study of biomimetic bone scaffolds based on the fusion of triply periodic minimal surfaces.BMC musculoskeletal disorders · 2025Article
- Impact of framework material, cantilever design, and wing configuration on stress distribution in patient specific additively manufactured subperiosteal jaw implants: a 3D finite element analysis.BMC oral health · 2025Article
- Design and optimisation of patient-specific porous femoral stems.Journal of orthopaedic surgery and research · 2025Article
- Stress-Strain State Investigation and Ultimate Load on Femoral Implants Based on S-Type Ti6Al4V Titanium Alloy.Journal of functional biomaterials · 2025Article
- Mandibular Implants: A Metamaterial-Based Approach to Reducing Stress Shielding.Advanced healthcare materials · 2025Article
- Advancements in 3D printing technologies for personalized treatment of osteonecrosis of the femoral head.Materials today. Bio · 2025Review
- A computational optimisation study of hip implant using density mapping functionally graded biomimetic TPMS-based lattice structures.NPJ metamaterials · 2025Article
- Selective laser melting fabrication of functionally graded macro-porous Ti-6Al-4V scaffold for cavity bone defect reconstruction.Frontiers in bioengineering and biotechnology · 2025Article
- Porous metal materials for applications in orthopedic field: A review on mechanisms in bone healing.Journal of orthopaedic translation · 2024Review
- Personalized Stem Length Optimization in Hip Replacement: A Microscopic Perspective on Bone-Implant Interaction.Bioengineering (Basel, Switzerland) · 2024Article
- Advanced porous hip implants: A comprehensive review.Heliyon · 2024Review
- Comparison In Vitro Study on the Interface between Skin and Bone Cell Cultures and Microporous Titanium Samples Manufactured with 3D Printing Technology Versus Sintered Samples.Nanomaterials (Basel, Switzerland) · 2024Article
- Advanced topology of triply periodic minimal surface structure for osteogenic improvement within orthopedic metallic screw.Materials today. Bio · 2024Article
- In Vivo Investigation of 3D-Printed Calcium Magnesium Phosphate Wedges in Partial Load Defects.Materials (Basel, Switzerland) · 2024Article
- Debulking of the Femoral Stem in a Primary Total Hip Joint Replacement: A Novel Method to Reduce Stress Shielding.Bioengineering (Basel, Switzerland) · 2024Article
- Optimizing efficiency in the creation of patient-specific plates through field-driven generative design in maxillofacial surgery.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Stress shielding secondary to bone resorption is one of the main causes of aseptic loosening, which limits the lifespan of hip prostheses and exacerbates revision surgery rates. In order to minimise post-hip replacement stress variations, this investigation proposes a low-stiffness, porous Ti6Al4V hip prosthesis, developed through selective laser melting (SLM). The stress shielding effect and potential bone resorption properties of the porous hip implant were investigated through both