ArticleBiomedical reports2023
Measurement of exhaled breath temperature in patients under general anesthesia: A feasibility study.
Article in Biomedical reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of the present study was to investigate the respiratory parameters that influence the exhaled breath temperature (EBT) and the feasibility of using the latter to monitor the core temperature under general endotracheal anesthesia. A total of 20 patients undergoing abdominal surgery were included in the present study. At the first stage of the experiment, the respiratory rate was adjusted, while the other respiratory parameters [tidal volume, inspiratory and expiratory time ratio (TI:TE), and positive end expiratory pressure (PEEP)] were maintained at a constant level. At the second stage, the tidal volume was adjusted, while the other respiratory parameters were maintained at a constant level. At the third stage, the TI:TE was adjusted, while the other parameters were maintained at a constant level. At the fourth stage, PEEP was adjusted, while the other parameters were maintained at a constant level. In each experiment, the EBT, the maximum temperature of exhaled air in each min, the inhaled air temperature and the nasopharyngeal temperature (T nose) were recorded every min. During the first stage of the experiment, no significant difference was noted in the EBT at different levels of respiratory rate. During the second, third and fourth stage, no significant difference was noted in the EBT at different tidal volumes, TI:TE and PEEP, respectively. The EBT was significantly correlated with the T nose. Overall, the present study demonstrated that the EBT of patients undergoing abdominal surgery under general endotracheal anesthesia was not affected by the examined respiratory parameters and that it could be considered a feasible method of monitoring core temperature.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.